WD3060 - WD5090
USER MANUAL
34
14
ROUTINE INSPECTIONS AND MAINTENANCE
14.1
DAILY
1.
Check the detergent and neutralising agent levels in the cans and fill up if necessary.
2.
Check spray arm rotation and inspect the water outlet holes visually to check that they are clean.
14.2
WEEKLY
1.
Clean the sump filters, following the instructions provided.
2.
Run program with a thermal disinfection phase, without instruments for processing in the appliance, for
precautionary cleaning/disinfection of the washing chamber.
14.3
EVERY SIX MONTHS
1.
Inspect the water solenoid valve intake filters; if necessary, clean them by pouring hot water through them in
the opposite direction to the operating flow.
2.
Inspect the intake and outlet hoses of the detergent and neutralising agent pumps.
14.4
EVERY YEAR
Contact your nearest authorised Service Centre to have the appliance completely checked over at the end of the
warranty period and annually for successive years, or, if this occurs before the end of the year, when the
“Appliance
maintenance”
LED illuminates.
Maintenance operations are not covered by the product Warranty
, which does not include the
replacement of components which deteriorate due to normal wear and tear.
The operations which the authorised staff will carry out are:
1.
Inspection and if necessary replacement of worn
peristaltic pump
components (especially the internal hose)
2.
Inspection of the
detergent intake
pipes
and replacement if necessary.
3.
Inspection of the
door gasket
and replacement if necessary.
4.
Inspection of the
drying system filters
(relative and absolute) and replacement if necessary.
5.
Inspection and if necessary cleaning/replacement of the
filters
(water intake filters on the filler pipes, detergent
filters on the suction systems).
6.
Checking of the intake
water hardness setting
(the user must first have the intake water analysed to allow the
correct settings to be made).
7.
Checking of the
detergent dosage settings.
8.
Inspection of the
steam condenser
assembly:
a.
Inspection of the
nozzles
, check that water is flowing correctly.
b.
Inspection of the connection, water intake, water drainage hose and level switch components
.
9.
Performance of a complete operating cycle
, including the drying phase, to check for any leaks or malfunctions.
WARNING
The manufacturer declines all responsibility in the event of appliance malfunctions, or injury or damage,
arising from the failure to comply with the above recommendations.