![Smeg WD1160 User Manual Download Page 22](http://html1.mh-extra.com/html/smeg/wd1160/wd1160_user-manual_1303014022.webp)
User Manual
WD2145-WD1160-WD4060-WD4190
Page 22 - 85
5.4
INDICATOR LEDS - DETAILED EXPLANATION
1 - Symbols associated to a warning
SYMBOL
MEANING
No detergent
Lights up if the detergent level sensors are installed and one of them is at "minimum" level.
The warning is displayed at the end of the cycle and, in combination with the LED, the segment
display shows the code of the detergent to which the warning refers:
P1: code “A-:68”
P2: code “A-:69”
P3: code “A-:70”
Activated at the end of the cycle and when the user attempts to start a new program.
The washing cycle can be started with this light on by pressing the
Start/Stop
button again.
If both alarms are present (cans P1 and P2 both empty), the
Start/Stop
button has to be
pressed twice to start the cycle. (The device’s internal memory records the event).
Replace the can of detergent which is running out with a new can as soon as possible.
Maintenance: filter replacement
Only for WD4060, WD4190 series. Active if the dryer is present and the absolute filter is
installed. (The absolute filter is optional on the GW series).
The LED indicates that the absolute filter needs to be replaced.
Operation of the light is triggered by the number of drying operating hours, set at 500h when
the filter is new. The filter must be replaced by authorised staff.
Appliance maintenance
The appliance counts the number of cycles performed and the LED comes on to alert the user
that maintenance is required.
These are inspection and maintenance operations, scheduled every 1000 cycles, which must be
performed by authorised staff to keep the appliance safe and in good working order.
Lack of Salt
Salt must be added to the water softener reservoir in the chamber.
Salt is necessary to enable the softener to reduce the hardness of the intake water.
Alarm
The machine displays an anomaly, which can be generated by a fault or by the detection of
abnormal conditions.
A numerical code on the segment display indicates the alarm which has
been triggered.
The alarms table in this manual details the components which may have
caused the event for each alarm code, to simplify diagnostics and troubleshooting.
A record should be kept of any alarms to allow the After-Sales Service to be provided with a
detailed description of the malfunction.