31
STAINED GLASSES AND CUTLERY
Rinse aid unsuitable or not being
delivered correctly.
Water hardness above 12°dF or
large amounts of dissolved salts
Check container of rinse aid and
whether type is suitable for the mains
water- If the problem persists, contact
the after-sales service.
WATER LEFT IN THE TANK AFTER
PUMP-OUT.
Waste tube badly positioned or
partially clogged.
Verify that the tube and drainage are
not clogged and that the drainage is
not positioned too high; see connection
scheme.
14
MALFUNCTIONS SHOWN ON THE DISPLAY (FOR THE USER)
The dishwasher can show a series of malfunctions on display.
After the machine has been switched off and restarted, if the problem is not solved, follow the steps below:
( FOR A MORE PROFICIENT AFTER-SALES SERVICE, ALWAYS TAKE NOTE OF THE INDICATED ERROR )
Err04
Tank temperature probe anomaly
Contact After-sales Service
Err05
Tank water filling anomaly
Check that the water supply tap is open, the dynamic supply
pressure, cleanliness of the inlet water filter. If the problem
still occurs, contact After-sales Service.
Err06
Water pump-out anomaly
(water remains in the dishwasher)
Check that the filters are clean, and that the drain pipe is not
bent, obstructed, narrowed.
Check that the drain pump is not blocked with a foreign body,
follow steps indicated in “10.2 Periodical checks”.
If the problem still occurs, contact After-sales Service.
Err09
Excessive water level in the tank anomaly
Contact After-sales Service
Err23
Boiler heating anomaly (does not heat)
Contact After-sales Service
Err24
Boiler temperature probe anomaly
Contact After-sales Service
Err25
Boiler water filling anomaly
Check that the water supply tap is open, the dynamic supply
pressure, cleanliness of the inlet water filter. If the problem
still occurs, contact After-sales Service.
Err26
Boiler emptying anomaly
Check that the nozzles of the rinsing spray arms are not
clogged.
If the problem still occurs, contact After-sales Service.
Err27
Boiler emptying anomaly – with full tank
Contact After-sales Service
Err28
Boiler heating anomaly (over temperature)
Contact After-sales Service
19.390.6831.02