RECOMMENDATIONS AND SUGGESTIONS

 

  The Instructions for Use apply to several versions of this appliance. Accordingly, you may find 

descriptions of individual features that do not apply to your specific appliance. 

INSTALLATION 

•  The manufacturer will not be held liable for any damages resulting from incorrect or improper 

installation. 

•  The minimum safety distance between the cooker top and the extractor hood is 650 mm (some 

models can be installed at a lower height, please refer to the paragraphs on working dimensions 

and installation). 

•  Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of 

the hood. 

•  For Class I appliances, check that the domestic power supply guarantees adequate earthing. 

  Connect the extractor to the exhaust flue through a pipe of minimum diameter 120 mm. The route 

of the flue must be as short as possible. 

•  Do not connect the extractor hood to exhaust ducts carrying combustion fumes (boilers, fireplaces, 

etc.). 

•  If the extractor is used in conjunction with non-electrical appliances (e.g. gas burning appliances), a 

sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of 

exhaust gas. The kitchen must have an opening communicating directly with the open air in order 

to guarantee the entry of clean air. When the cooker hood is used in conjunction with appliances 

supplied with energy other than electric, the negative pressure in the room must not exceed 0,04 

mbar to prevent fumes being drawn back into the room by the cooker hood. 

•  In the event of damage to the power cable, it must be replaced by the manufacturer or by the 

technical service department, in order to prevent any risks.  

•  If the instructions for installation for the gas hob specify a greater distance specified above, this has 

to be taken into account. Regulations concerning the discharge of air have to be fulfilled. 

  “WARNING: Failure to install the screws or fixing device in accordance with these instructions may 

result in electrical hazards.” 

USE 

•  The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells. 

•  Never use the hood for purposes other than for which it has been designed. 

•  Never leave high naked flames under the hood when it is in operation. 

•  Adjust the flame intensity to direct it onto the bottom of the pan only, making sure that it does not 

engulf the sides. 

•  Deep fat fryers must be continuously monitored during use: overheated oil can burst into flames. 

•  Do not flambè under the range hood; risk of fire  

•  This appliance is not intended for use by persons (including children) with reduced physical, sen-

sory or mental capabilities, or lack of experience and knowledge, unless they have been given su-

pervision or instruction concerning use of the appliance by a person responsible for their safety. 

•  Children should be supervised to ensure that they do not play with the appliance. 

• “WARNING: Accessible parts may become hot when used with cooking appliances.”. 

MAINTENANCE 

•  Switch off or unplug the appliance from the mains supply before carrying out any maintenance 

work. 

•  Clean and/or replace the Filters after the specified time period (Fire hazard). 

•  Clean the hood using a damp cloth and a neutral liquid detergent. 

 

The symbol 

 on the product or on its packaging indicates that this product may not be treated as household waste. Instead it 

shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product 
is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could 
otherwise be caused by inappropriate waste handling of this product. For more detailed information about recycling of this product, 
please contact your local city office, your household waste disposal service or the shop where you purchased the product. 

 

 

Summary of Contents for STH600X

Page 1: ...Instructions Manual STH600X STH900X ...

Page 2: ...2 2 INDEX RECOMMENDATIONS AND SUGGESTIONS 3 CHARACTERISTICS 4 INSTALLATION 5 USE 7 MAINTENANCE 8 EN ...

Page 3: ...e thishas tobetakenintoaccount Regulationsconcerningthedischargeofairhavetobefulfilled WARNING Failuretoinstallthescrewsorfixingdeviceinaccordancewiththeseinstructionsmay resultinelectricalhazards USE Theextractorhoodhasbeendesignedexclusivelyfordomesticusetoeliminatekitchensmells Neverusethehoodforpurposesotherthanforwhichithasbeendesigned Neverleavehighnakedflamesunderthehoodwhenitisinoperation ...

Page 4: ... Body complete with Controls Light Blower Filters 8 1 Directional Air Outlet grille 9 1 Reducer Flange ø 150 120 mm 10 1 Damper ø 150 20 1 Closing element Ref Q ty Installation Components 12a 4 Screws 4 2 x 44 4 12b 2 Screws 4 2 x 12 7 12e 2 Screws 2 9 x 9 5 Q ty Documentation 1 Instruction Manual 12b ...

Page 5: ...4 4 provided 12a 135 150 SNAP ON FITTING The hood can be installed either directly on the bottom surface of the wall units using snap on side supports Cut a fitted opening in the bottom surface of the wall unit as shown Insert the hood until the side supports snap into place Lock in position by tightening the screws Vf from underneath the hood Hood Type 45 50 55 60 70 80 90 L1 360 410 460 510 610 ...

Page 6: ...20 ø150 10 10 9 RECIRCULATION VERSION AIR OUTLET Cut a hole ø 125 mm in any shelf that may be posi tioned over the hood Insert the reducer flange 9 on the hood body outlet Connect the flange to the outlet on the shelf over the hood by using a flexible or rigid pipe ø120 mm Fix the pipe in position using sufficient pipe clamps not supplied Fix the air outlet grid 8 on the recirculation air outlet b...

Page 7: ... given the optimum treated air flow noise level ratio 3 Maximum speed used for eliminating the highest cooking vapour emission including long periods L Light Switches the lighting system on and off M Motor Switches the extractor motor on and off V Speed Sets the operating speed of the extractor 1 Low speed used for a continuous and silent air change in the presence of light cooking vapour 2 Medium...

Page 8: ...ersion REPLACINGCHARCOALFILTERS Warning Turn the lights off and wait until the lamps cool down before you change the odour filter These filters are not washable and cannot be regenerated and must be replaced approximately every four months or more frequently by par ticularly heavy use Pull out the sliding suction panel Remove the grease filters Remove the saturated carbon filter by releasing the f...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ...991 0319 368_ver2 ...

Reviews: