Hood body mounting 

•  Firstly, it is necessary to adjust the two 

Vr-

screws of 

the 

11a-

brackets, at minimun (

B

). 

•  Hang the hood body on the two brackets 

11a

•  Connect the hood to the mains supply by means of a 

bipolar switch with at least 3 mm contact gap. 

• Press the “

A

”-key for one second (see Part USE) to 

open the upper panel. 

•  Remove the metal filters.   
•  In order to align the hood it is necessary to adjust the 

Vr-

screws from inside the hood. 

 •  Fasten the safety screw 

11

•  Fit again the metal filters into their seats and close the 

upper panel by pressing “

L

”-key for one second (see 

Part USE). 

•  Disconnect the hood from the mains supply. 

   

  Attention: the upper panel stops if any barrier occurs in its 

way during the panel opening or closing. To open the panel 

it is enough to remove the barrier and press the key once 

again. 

 

( B )

11a

Vr

11

Connections 

DUCTED VERSION AIR EXHAUST SYSTEM 

When installing the ducted version, connect the hood to 
the chimney using either a flexible or rigid pipe ø 150 
or 120mm, the choice of which is left to the installer. 

To install a ø 150 pipe 

•  To install the dumper 

10

 

•  Fix the pipe in position using sufficient pipe clamps 

(not supplied). 

To install a ø 120 pipe 

•  To install a ø 120 mm air exhaust connection, insert 

the reducer flange 

9

 on the dumper 

10

•  Fix the pipe in position using sufficient pipe clamps 

(not supplied). 

•  Remove any activated charcoal filters. 

ø 120

ø 150

10

10

9

Summary of Contents for SHW800B

Page 1: ...Instructions Manual SHW800B ...

Page 2: ...2 2 INDEX RECOMMENDATIONS AND SUGGESTIONS 3 CHARACTERISTICS 4 INSTALLATION 6 USE 9 MAINTENANCE 11 EN ...

Page 3: ...ks WARNING Failuretoinstallthescrewsorfixingdeviceinaccordancewiththeseinstructionsmay resultinelectricalhazards USE Theextractorhoodhasbeendesignedexclusivelyfordomesticusetoeliminatekitchensmells Neverusethehoodforpurposesotherthanforwhichithasbeendesigned Neverleavehighnakedflamesunderthehoodwhenitisinoperation Adjust the flame intensity to direct it onto the bottom of the pan only making sure ...

Page 4: ...1 Air outlet grid 9 1 Reducer flange Ø 150 120 10 1 Damper 16 1 Cover for recycling version Ref Q ty Installation components 7 2 1 2 Fixing brackets for upper chimney 11 5 Plugs 11a 2 Plugs SB 12 10 12a 5 Screws 4 2 x 44 4 12c 10 Screws 2 9 x 6 5 12e 2 Screws 2 9 x 9 5 Q ty Documentation 1 Instruction booklet 2 1 2 2 12c 12a 7 2 1 11 11 12a 10 9 1 16 12c 12d 8 11a ...

Page 5: ...EN 5 5 Dimensions Min 368mm Min 368mm ...

Page 6: ...l reference line Drill at the marked points 1 using a ø 12 mm drill bit Drill at the marked point 3 using a ø 8 mm drill bit Insert the bracket plugs 11a into the holes 1 and tighten the screws Insert plug 11 into hole 3 Place bracket 7 2 1 on the wall about 1 2 mm from the ceiling or from the upper limit aligning the centre notch with the vertical reference line Mark the wall at the centres of th...

Page 7: ...the hood from the mains supply Attention the upper panel stops if any barrier occurs in its way during the panel opening or closing To open the panel it is enough to remove the barrier and press the key once again B 11a Vr 11 Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version connect the hood to the chimney using either a flexible or rigid pipe ø 150 or 120mm the choi...

Page 8: ...at least 2 seconds Remove the metal filters See Part MAINTE NANCE and make sure that the connector piece of the supply cable is correctly inside the hood socket Chimney assembly Upper exhaust Chimney Slightly widen the two sides of the upper chimney and hook them behind the brackets 7 2 1 making sure that they are well seated Secure the sides to the brackets using the 4 screws 12c 2 9 x 9 5 suppli...

Page 9: ...essed for approximately 3 seconds when all the users motor lights are turned off After 100 hours in operation the Drop sym bol is displayed to indicate saturation of the Metal Grease Filters After 200 hours in operation the letter C is displayed to indicate saturation of the Acti vated Charcoal filters H Modifies the intensity of the Lighting each time the Button is pressed in cycle I Door Closed ...

Page 10: ...panel is open T3 Motor Upper panel closed opens the upper panel switches on the motor at the latest se lected speed Upper panel open switches the motor on off When pressed for about 2 Seconds upper panel closed opens the upper panel and switches on the motor at the third speed and the lights at the maximum intensity Upper panel open switches off lights and motor and closes the upper panel T4 Decre...

Page 11: ...ssing the A key for 1 second see Part USE Remove the filters one by one pushing them towards the back side of the hood unit and simultaneously pulling downwards Any kind of bending of the filters has to be avoided when washing them Before fitting them again into the hood make sure that they are completely dry The colour of the filter sur face may change throughout the time but this has no influenc...

Page 12: ...ash Within 3 seconds press the D key to activate deactivate charcoal filter saturation alarm C symbol lit charcoal filter saturation alarm ACTIVATED C symbol unlit charcoal filter saturation alarm DEACTIVATED REPLACING THE CHARCOAL FILTER Alarm reset Press the G key for at least 2 seconds Replacing the filter Open the upper panel by pressing the A key for about a second see Part USE Remove the met...

Page 13: ...EN 1 13 Replacing the fuser The fuser is placed up on the right side Turn the fuser holder as indicated Replace the fuser with one having the same features ...

Page 14: ......

Page 15: ......

Page 16: ...991 0266 554_ver1 ...

Reviews: