Smeg SHW800B Instruction Manual Download Page 9

 

 

 

 

 

EN 

9

 

USE

 

Control panel 

B

A

D

C

E

G

F

I

H

L

 

 

Button Function 

Display 

Door Closed: Press and hold for approximately 2 Sec-
onds to open the door and turn the motor on at the last 
speed set. 
Door Open: Press briefly to turn the motor Off or On. 

Displays the set speed. 

Decrease the working speed. 

The number of lighted segments decreases. 

Increase the working speed. 

The number of lighted segments increases. 

Can only be activated with Door Open. This speed is 
timed to run for 10 minutes. At the end of this time the 
system will automatically return to the speed set before. 
Suitable to deal with maximum levels of cooking fumes. 

The indicator 

I

 flashes and all the segments 

on the Display are lit. 
 
It is disabled by pressing the Button. 

Can only be activated with Door Open. Starts the Motor 
at a speed that allows suction of 100 m3/h. Cannot be 
activated if Intensive or Delay are active.  

Displays 

24

 and the segments on the Display 

all light up and then turn off one at a time in 
cycle. 
It is disabled by pressing the Button. 

Can be activated with motor on (except for intensive and 
24 mode). Activates automatic shutdown of the Motor 
and the Lighting with a 30’ delay.  

Displays a flashing 

Clock

 symbol. 

 
It is disabled by pressing the Button. 

Performs a 

Reset

 of the Filter saturation alarm when the 

button is pressed for approximately 3 seconds when all 
the users (motor + lights) are turned off. 

After 100 hours in operation the 

Drop

 sym-

bol is displayed to indicate saturation of the 
Metal Grease Filters. 
After 200 hours in operation the letter 

C

 is 

displayed to indicate saturation of the Acti-
vated Charcoal filters.  

Modifies the intensity of the Lighting each time the 
Button is pressed, in cycle. 

 

Door Closed:  

When pressed and held for approximately 2 seconds 
opens the door half way and turns the lighting on to 
maximum intensity. The intensity can be modified using 
button 

H

- When the button is pressed again, the lighting turns off 

and the door closes. 

- Press 

for door fully open, motor at speed three and 

lighting on. 

- When button 

A

 is pressed the lights turn on and the 

motor operates at the first two speeds only. 

Door Open: Press briefly to turn the lighting On or Off. 

 

Door Closed: Press and hold for approximately 2 Sec-
onds to open the door, turn the motor on at speed three 
and turn the lighting on at maximum intensity. 
Door Open: When pressed and held for approximately 2 
seconds turns off the motor and the lighting, cancelling 
any function that may be active and closing the door. 

 

Keyboard Lock: it is possible to lock the keyboard, for example when cleaning the Glass, when the Hood has Motor and 
Lights turned off and when no alarms have been triggered.

 

Press 

F

 (Delay) for approximately 5 Seconds to enable or disable the Keyboard Lock, which is always confirmed by a 

Beep and an animation on the display motor bar.

 

 

Summary of Contents for SHW800B

Page 1: ...Instructions Manual SHW800B ...

Page 2: ...2 2 INDEX RECOMMENDATIONS AND SUGGESTIONS 3 CHARACTERISTICS 4 INSTALLATION 6 USE 9 MAINTENANCE 11 EN ...

Page 3: ...ks WARNING Failuretoinstallthescrewsorfixingdeviceinaccordancewiththeseinstructionsmay resultinelectricalhazards USE Theextractorhoodhasbeendesignedexclusivelyfordomesticusetoeliminatekitchensmells Neverusethehoodforpurposesotherthanforwhichithasbeendesigned Neverleavehighnakedflamesunderthehoodwhenitisinoperation Adjust the flame intensity to direct it onto the bottom of the pan only making sure ...

Page 4: ...1 Air outlet grid 9 1 Reducer flange Ø 150 120 10 1 Damper 16 1 Cover for recycling version Ref Q ty Installation components 7 2 1 2 Fixing brackets for upper chimney 11 5 Plugs 11a 2 Plugs SB 12 10 12a 5 Screws 4 2 x 44 4 12c 10 Screws 2 9 x 6 5 12e 2 Screws 2 9 x 9 5 Q ty Documentation 1 Instruction booklet 2 1 2 2 12c 12a 7 2 1 11 11 12a 10 9 1 16 12c 12d 8 11a ...

Page 5: ...EN 5 5 Dimensions Min 368mm Min 368mm ...

Page 6: ...l reference line Drill at the marked points 1 using a ø 12 mm drill bit Drill at the marked point 3 using a ø 8 mm drill bit Insert the bracket plugs 11a into the holes 1 and tighten the screws Insert plug 11 into hole 3 Place bracket 7 2 1 on the wall about 1 2 mm from the ceiling or from the upper limit aligning the centre notch with the vertical reference line Mark the wall at the centres of th...

Page 7: ...the hood from the mains supply Attention the upper panel stops if any barrier occurs in its way during the panel opening or closing To open the panel it is enough to remove the barrier and press the key once again B 11a Vr 11 Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version connect the hood to the chimney using either a flexible or rigid pipe ø 150 or 120mm the choi...

Page 8: ...at least 2 seconds Remove the metal filters See Part MAINTE NANCE and make sure that the connector piece of the supply cable is correctly inside the hood socket Chimney assembly Upper exhaust Chimney Slightly widen the two sides of the upper chimney and hook them behind the brackets 7 2 1 making sure that they are well seated Secure the sides to the brackets using the 4 screws 12c 2 9 x 9 5 suppli...

Page 9: ...essed for approximately 3 seconds when all the users motor lights are turned off After 100 hours in operation the Drop sym bol is displayed to indicate saturation of the Metal Grease Filters After 200 hours in operation the letter C is displayed to indicate saturation of the Acti vated Charcoal filters H Modifies the intensity of the Lighting each time the Button is pressed in cycle I Door Closed ...

Page 10: ...panel is open T3 Motor Upper panel closed opens the upper panel switches on the motor at the latest se lected speed Upper panel open switches the motor on off When pressed for about 2 Seconds upper panel closed opens the upper panel and switches on the motor at the third speed and the lights at the maximum intensity Upper panel open switches off lights and motor and closes the upper panel T4 Decre...

Page 11: ...ssing the A key for 1 second see Part USE Remove the filters one by one pushing them towards the back side of the hood unit and simultaneously pulling downwards Any kind of bending of the filters has to be avoided when washing them Before fitting them again into the hood make sure that they are completely dry The colour of the filter sur face may change throughout the time but this has no influenc...

Page 12: ...ash Within 3 seconds press the D key to activate deactivate charcoal filter saturation alarm C symbol lit charcoal filter saturation alarm ACTIVATED C symbol unlit charcoal filter saturation alarm DEACTIVATED REPLACING THE CHARCOAL FILTER Alarm reset Press the G key for at least 2 seconds Replacing the filter Open the upper panel by pressing the A key for about a second see Part USE Remove the met...

Page 13: ...EN 1 13 Replacing the fuser The fuser is placed up on the right side Turn the fuser holder as indicated Replace the fuser with one having the same features ...

Page 14: ......

Page 15: ......

Page 16: ...991 0266 554_ver1 ...

Reviews: