Installation
25
EN
Extraction of the combustion products
The combustion products may be extracted
by means of hoods connected to a natural
draught chimney whose efficiency is certain
or via forced extraction. An efficient
extraction system requires precision
planning by a specialist qualified in this
area and must comply with the positions.
and distances indicated by the applicable
standards.
1
Extraction using a hood
2
Extraction without a hood
A
Single natural draught chimney
B
Single chimney with extractor fan
C
Directly outdoors with wall- or window-
mounted extractor fan
D
Directly outdoors through wall
Air
Combustion products
Extractor fan
5.7 Adaptation to different types of
gas
If other types of gas are to be used, the
nozzles must be replaced and the primary
air must be adjusted. In order to replace the
nozzles and adjust the burners, the hob top
must be removed.
Removing the hob top
1. Remove the grids from the top; first the
centre one than the lateral ones.
2. Remove the flame-spreader crowns and
relative burner caps.
This domestic appliance is not
connected to a device for
extracting combustion products. It
must be installed and connected in
accordance with current
installation regulations. Pay
particular attention to the relevant
requirements regarding ventilation.