3. ELECTRICAL CONNECTION

 

 

Make sure that the voltage and capacity of the power line conform to the 
data shown on the plate located under the casing. 

Do not remove this 

plate for any reason.

 

 

 

The plug on the end of the supply cable and the wall socket must be the 
same type and conform to the current electrical system regulations. 
Check that the power line is adequately grounded. 

 

 

On the power line, install an omnipolar cut-off device with contact cut-off 
distance greater than or equal to 

3 mm

, located in an easily accessible 

position near the unit. 

 

 

Do not use reducers, adapters or shunts. 

 
 

 

 

 

 

If the power cable is replaced, the wire section on the new cable must 
not be less than 0.75 mm

2

 (3 x 0.75 cable), keeping in mind that the end 

to be connected to the hob must have the ground wire (yellow-green) 
longer by at least 20 mm. Use only H05V2V2-F cable or similar which has 
a maximum temperature of 90°C. Any replacement needed should be 
carried out by a specialised technician who should make the mains 
connections according to the following diagram. 

 

L

 = brown 

N

 = blue 

 = yellow-green

 

 

 

 

 

 

 

 

The manufacturer will not be liable

for any damage to persons or 

property caused by non-observance of the above instructions or deriving 
from the tampering of even a single part of the hob. 

 

Summary of Contents for ER 17250

Page 1: ...Istruzioni per l uso Directions for use Instrucciones de manejo Instru es de Servi o Mode d emploi Gebrauchsanleitung Gebruiksaanwijzing ER 17651 ER 17450 ER 17350 ER 17250 ER 37220...

Page 2: ...cemos por ter escolhido este nosso produto Aconselhamos a leitura atenta deste manual onde se encontram todas as indica es para manter inalteradas as qualidades est ticas e funcionais da placa de fog...

Page 3: ...B _________________________________________30 8 CLEANING AND MAINTENANCE ____________________________32 THESE INSTRUCTIONS ARE VALID ONLY FOR END USER COUNTRIES WHOSE IDENTIFICATION SYMBOLS APPEAR ON...

Page 4: ...CONSIDERED IMPROPER THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR IMPROPER USE DO NOT LEAVE THE PACKING IN THE HOME ENVIRONMENT SEPARATE THE VARIOUS WASTE MATERIALS AND TAKE THEM TO THE NEAREST SPE...

Page 5: ...PERFECTLY SMOOTH AND FLAT BOTTOMS ON THE COOKING HOB GRIDS DO NOT USE RECIPIENTS OR GRIDDLE PLATES THAT EXTEND BEYOND THE EXTERNAL PERIMETER OF THE HOB THE HOB IS TO BE USED BY ADULTS ONLY DO NOT LET...

Page 6: ...walls that are higher than the work surface provided that a distance of 145 mm is respected as shown in the figure to prevent damage due to overheating Make sure there is a minimum of 750 mm between...

Page 7: ...accessible position near the unit Do not use reducers adapters or shunts If the power cable is replaced the wire section on the new cable must not be less than 0 75 mm 2 3 x 0 75 cable keeping in mind...

Page 8: ...inspected for G20 2H natural gas at a pressure of 20 mbar For use with other types of gases see Section 5 ADAPTATION TO DIFFERENT TYPES OF GAS The gas intake fitting is gas external threaded ISO 228...

Page 9: ...intakes protected by screens must be appropriately sized regulations in force and placed so as not to be blocked in any way The room where the oven is installed should be suitably ventilated to avoid...

Page 10: ...e replaced and the primary air adjusted To replace the nozzles and regulate the burners you have to remove the top as described in the following paragraph 5 1 Removing the hob 1 Remove all the knobs t...

Page 11: ...rt in paragraph 5 4 Regulation of primary air and then secure the tube by means of screw A After the regulations have been carried out restore the seals with sealing wax or equivalent material Burner...

Page 12: ...out restore the seals with sealing wax or equivalent material Burner Rated heating capacity kW Natural gas G20 20 mbar Nozzle diameter 1 100 mm Reduced flowrate W Auxiliary 1 1 05 73 380 Semi rapid 2...

Page 13: ...he model until you get a suitable minimum flame Replace the knob and check burner flame stability rapidly turning the knob from maximum to minimum position the flame should not go out 6 2 Regulation o...

Page 14: ...1 Auxiliary 2 Semi rapid 3 Average rapid 4 Large rapid 5 6 Triple crown 7 Double crown 6 4 Lubrication of gas taps After a while the gas tap may become hard to turn or lock If this happens it has to b...

Page 15: ...flame burning and to activate the safety device The burner might go off when the knob is released In this case repeat the aforesaid operation keeping the knob pressed for more than 2 seconds Should th...

Page 16: ...nstructions for the user 31 7 3 Diameter of containers BURNERS 1 Auxiliary 2 Semi rapid 3 Average rapid 4 Large rapid 5 6 Triple crown 7 Double crown min e max in cm 7 18 10 24 12 24 14 28 22 26 12 34...

Page 17: ...stains or residues Do not use metallic sponges or sharp scrapers they will damage the surface Use normal non abrasive products and remove spots or residuals with non scratch sponges or if need be wit...

Reviews: