background image

 

 

Instructions for the installer

 

 

26

 

5.2 Regulation for LPG

Loosen screw 

A

 and push support 

B

 all the way. Use a double head 

wrench to remove nozzle 

C

 and assemble the suitable one, following the 

instructions indicated in the reference charts, with respect to the type of 
gas to use. The screwing torque of the nozzle should never exceed      

3 Nm

. Reposition support 

B

 so that nozzle 

C

 is covered perfectly. 

Move the Venturi tube 

D

 to regulate the air flow until distance "

X

" is 

reached indicated in the chart in paragraph "5.4 Regulation of primary air” 
and then secure the tube by means of screw 

A

.  After the regulations 

have been carried out, restore the seals with sealing wax or equivalent 
material.

 

 
  
 
 
 
 
 

 

 

 
 
 
 
 
 
 

 
Burner 

Rated 

heating 

capacity 

(kW) 

 

LPG – G30/G31

  28/37 mbar

 

 

 

Nozzle 

diameter 

1/100 mm 

By-pass 

mm 

1/100 

Reduced 

flowrate 

(W) 

Flowrate 

g/h G30 

Flowrate 

g/h G31 

Auxiliary (1) 

1.05 

48 

30 

33 (*) 

380 

76 

75 

Semi-rapid (2) 

1.65 

62 

30 

33 (*) 

380 

120 

118 

Average rapid (3) 

2.55 

76 

37 

40 (*) 

750 

185 

182 

Large rapid (4) 

3.1 

85 

45 

800 

225 

222 

Triple crown (5) 

3.9 

95 

65 

1700 

283 

279 

Triple crown (6) 

3.3 

87 

65 

1700 

240 

236 

internal (7) 

0.8 

42 

26 

33 (*) 

380 

58 

57 

Double crown 

external (7) 

3.3 

87 

55 

1200 

240 

236 

 
(*) By-pass value for valveless appliances. 
 

Summary of Contents for ER 17250

Page 1: ...Istruzioni per l uso Directions for use Instrucciones de manejo Instru es de Servi o Mode d emploi Gebrauchsanleitung Gebruiksaanwijzing ER 17651 ER 17450 ER 17350 ER 17250 ER 37220...

Page 2: ...cemos por ter escolhido este nosso produto Aconselhamos a leitura atenta deste manual onde se encontram todas as indica es para manter inalteradas as qualidades est ticas e funcionais da placa de fog...

Page 3: ...B _________________________________________30 8 CLEANING AND MAINTENANCE ____________________________32 THESE INSTRUCTIONS ARE VALID ONLY FOR END USER COUNTRIES WHOSE IDENTIFICATION SYMBOLS APPEAR ON...

Page 4: ...CONSIDERED IMPROPER THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR IMPROPER USE DO NOT LEAVE THE PACKING IN THE HOME ENVIRONMENT SEPARATE THE VARIOUS WASTE MATERIALS AND TAKE THEM TO THE NEAREST SPE...

Page 5: ...PERFECTLY SMOOTH AND FLAT BOTTOMS ON THE COOKING HOB GRIDS DO NOT USE RECIPIENTS OR GRIDDLE PLATES THAT EXTEND BEYOND THE EXTERNAL PERIMETER OF THE HOB THE HOB IS TO BE USED BY ADULTS ONLY DO NOT LET...

Page 6: ...walls that are higher than the work surface provided that a distance of 145 mm is respected as shown in the figure to prevent damage due to overheating Make sure there is a minimum of 750 mm between...

Page 7: ...accessible position near the unit Do not use reducers adapters or shunts If the power cable is replaced the wire section on the new cable must not be less than 0 75 mm 2 3 x 0 75 cable keeping in mind...

Page 8: ...inspected for G20 2H natural gas at a pressure of 20 mbar For use with other types of gases see Section 5 ADAPTATION TO DIFFERENT TYPES OF GAS The gas intake fitting is gas external threaded ISO 228...

Page 9: ...intakes protected by screens must be appropriately sized regulations in force and placed so as not to be blocked in any way The room where the oven is installed should be suitably ventilated to avoid...

Page 10: ...e replaced and the primary air adjusted To replace the nozzles and regulate the burners you have to remove the top as described in the following paragraph 5 1 Removing the hob 1 Remove all the knobs t...

Page 11: ...rt in paragraph 5 4 Regulation of primary air and then secure the tube by means of screw A After the regulations have been carried out restore the seals with sealing wax or equivalent material Burner...

Page 12: ...out restore the seals with sealing wax or equivalent material Burner Rated heating capacity kW Natural gas G20 20 mbar Nozzle diameter 1 100 mm Reduced flowrate W Auxiliary 1 1 05 73 380 Semi rapid 2...

Page 13: ...he model until you get a suitable minimum flame Replace the knob and check burner flame stability rapidly turning the knob from maximum to minimum position the flame should not go out 6 2 Regulation o...

Page 14: ...1 Auxiliary 2 Semi rapid 3 Average rapid 4 Large rapid 5 6 Triple crown 7 Double crown 6 4 Lubrication of gas taps After a while the gas tap may become hard to turn or lock If this happens it has to b...

Page 15: ...flame burning and to activate the safety device The burner might go off when the knob is released In this case repeat the aforesaid operation keeping the knob pressed for more than 2 seconds Should th...

Page 16: ...nstructions for the user 31 7 3 Diameter of containers BURNERS 1 Auxiliary 2 Semi rapid 3 Average rapid 4 Large rapid 5 6 Triple crown 7 Double crown min e max in cm 7 18 10 24 12 24 14 28 22 26 12 34...

Page 17: ...stains or residues Do not use metallic sponges or sharp scrapers they will damage the surface Use normal non abrasive products and remove spots or residuals with non scratch sponges or if need be wit...

Reviews: