3
2
Technical characteristics
TECHNICAL CHARACTERISTICS
CWC500R
Input voltage power
V
400V 3N ~
- transformable to version
V
230V-3 ~
Frequency
Hz 50
Max. absorbed power at 400V 3N ~
kW
11,1
Boiler resistance power at 400V 3N ~
kW
10,0
Tank resistance power
kW
3,0
Water supply pressure
kPa (bar)
200-400 (2 ÷ 4)
Water supply temperature
°C
50°C – 60°C
Water supply hardness
°dF
7°dF-12°dF
Rinse cycle water consumption
l
3,9
Boiler capacity
l
9
Tank capacity
l 35
Standard cycle duration with water supply at 50°C
s
90/120/180/c
Noise level
dB(A) 67
Protection rating
IPX
4
Net weight
kg 127
Power cable type
◄
HAR
►
H07RN-F
Electrical scheme - legend
PV Tank
Pressostat
ISP
Door Safety Switch
STV
Tank Temperature Sensor
STB
Boiler Temperature Sensor
TRB
Boiler Resistance Remote Control Switch (Coil)
TRV
Tank Resistance Remote Control Switch (Coil)
E Rinse
Electrovalve
DB
Rinse-aid Metering Unit
P Wash
Pump
DD
Detergent Metering Unit
PBT
Break Tank Pressostat
PR Rinse
pump
TP
Wash Pump Remote Control Switch (Coil)
TPL Wash
Pump
Thermal
TS
Safety Thermostat
F Antistatic
filters
Electrical Scheme – voltage regulation
R
S
T
R
S
T
400/3 Volt
230/3 Volt
TRB
400/3 Volt
TRB
230/3 Volt
Wash Pump
Boiler Resistance
Summary of Contents for CWC500R