Instructions for the Installer
12
3.3
Burner and Nozzle Data Tables (90 cm Models)
Burner
Rated
heat
capacity
(kW)
BOTTLED GAS - G30/G31
30/37 mbar
Nozzle
diameter
1/100 mm
By-pass
mm
1/100
Reduced
heat capacity
(W)
Flow-rate
g/h G30
Flow-rate
g/h G31
Auxiliary
1
50
30
350
73
71
Semi-rapid
1.75
65
33
450
127
125
Rapid
3
85
45
800
218
214
Triple Flame
3.2
91
65
1500
233
229
Fish
1.9
68
45
800
138
136
Oven
3.2
87
48
850
233
229
Maxi oven
5.2
110
59
1200
378
371
Grill
2.9
87
//
//
218
214
Maxi grill
4.0
100
//
//
291
286
Burner
Rated
heat
capacity
(kW)
TOWN GAS – G110
8 mbar
Nozzle diameter
1/100 mm
Reduced heat capacity
(W)
Auxiliary
1
145
350
Semi-rapid
1.75
190
450
Rapid
3
260
800
Triple Flame
3.5
290
1500
Fish
1.9
190
800
G110 gas cannot be used in models with gas oven.
The data for town gas refer to category III 1a2H3+ appliances.
Burner
Rated
heat
capacity
(kW)
NATURAL GAS - G20
20 mbar
Nozzle diameter
1/100 mm
Reduced heat capacity
(W)
Auxiliary
1
72
350
Semi-rapid
1.75
97
450
Rapid
3
115
800
Triple Flame (4)
3.5
133
1500
Triple Flame (8)
3.5
140
1500
Fish
1.9
94
800
Oven
3.2
130
850
Maxi oven
5.2
164
1200
Grill
2.9
130
//
Maxi grill
4.0
150
//