damaged
In case of such alarm follow this procedure:
1. If such alarm is present even when you turn on, turn off the system and disconnect
the power cable between the inverter and the corresponding motor.
2. Turn on the system again, then:
●
If the alarm is
not active
and the motor wirings are correct, replace the motor
●
If the alarm is still
active
, replace the AC-M1;
Low battery alarm:
●
Alarm code
: 12
●
Alarm level
: 3
●
Alarm cause
: the battery voltage level is lower than the minimum charge value
In case of such alarm, follow this procedure:
1. Check the battery level indication; if its value is below the
Battery Reset Value,
recharge
the battery, and check it.
2. If the battery is recharged and its voltage is correct but the display shows a
discharge value, check with the tester the battery voltage; if it is different from the
value reported on COMPACT display, call service to trim again the battery measure.
Motor current sensor alarm:
●
Alarm code
:
○
for drive motor: 15
○
for pump motor: 36
●
Alarm level
: 1
●
Alarm cause
: failure of current sensor
In case of such alarm, call the service to trim values, or replace the AC-M1.
Main breaker fault:
●
Alarm code
: 17
●
Alarm level
: 1
●
Alarm cause
: failure of the main breaker command.
In case of such alarm, follow this procedure:
1. Check the coil wirings; if they are ok, check the breaker coil resistance; if it is faulty,
PRELIMINARY VERSION
41
Summary of Contents for AC-M1
Page 1: ...AC M1 AC M1 PRELIMINARY VERSION...
Page 9: ...Figure 1 AC M1 All the dimensions are in millimetres PRELIMINARY VERSION 9...
Page 13: ...Figure 2 Planarity specifications for the AC M1with aluminium baseplate PRELIMINARY VERSION 13...
Page 21: ...Figure 3 General electrical vehicle PRELIMINARY VERSION 21...
Page 32: ...Figure 5 Interconnection cable PRELIMINARY VERSION 32...
Page 36: ...Figure 9 Drawing of COMPACT display slot PRELIMINARY VERSION 36...