background image

VR51-TF2Z003EN-A 

 

Page 3 of 3 

 

8 Limitations of Use - continued 

  Do not use the product with a pressure under 0.25 MPa. The time lag 

for  operating  the  VR51  is  different  depending  on  the  operating 
pressure. The higher the operating pressure, the shorter the time lag, 
and vice versa. If used under 0.25 MPa, an output will be produced; 
however, safety is not likely to be maintained, even though the time lag 
may exceed 0.5 seconds. 

 Caution 

8.3  Low temperature operation 

In the case of using in low temperature, take measures not to freeze the 
drainage or moisture. 

8.4  Trouble shooting 

Symptom 

Possible fault 

Action 

Note)

 

Cylinder does 
not operate 

Supply pressure is too low 

Check supply pressure 

Time difference between P1 
and P2 is more than 0.5 s. 

Check & ensure P1 and P2 is 
supplied within 0.5 s time 
difference. 

Start-up valves (push button 
operated) malfunction. 

Check if valves are operating 
correctly. 

Control valve faulty 

Refer to 9 Product Failure Modes. 

Start-up valve is 2 port 

Replace 2 port with 3 port valve 

Piping lengths P1 & P2 are 
not same 

Ensure P1 and P2 are same length 

Output does 
not turn off 

Start-up valve is 2 port 

Replace 2 port with 3 port valve 

Table 3. 

Note: If there are doubts about the performance of the unit, replace the whole unit. 

8.5  Limitations 

 Caution 

  This product is CE/UKCA marked as a safety component as defined 

under the Machinery Directive 2006/42/EC / The Supply of Machinery 
(safety) Regulations 2008. For details, please refer to the Declaration 
of Conformity supplied with the product.   

  The valve may only be used to provide the stated safety function as a 

logic  unit  for  use  in  two-hand  control  circuits.  The  valve  can  only 
perform  as  a  safety  component  when  properly  installed  in  a  system 
conforming to the appropriate safety standards.  

  Any  such  use  must  be  within  the  specified  limits  and  application 

conditions for the product.  

  In  order  to  meet  a  required  performance  level  as  defined  by  the 

appropriate  safety  standard,  the  user  must  provide  all  the  other 
necessary components to complete function of the safety system. 

  The user is responsible for the specification, design, implementation, 

validation and maintenance of the safety system. 

9 Product Failure Modes 

 Warning 

Failure mode 

Cause 

Action 

Malfunction allowing output by 
one-handed operation. 

Ingress of foreign matter 

Please 

replace 

the 

product.  

Malfunction allowing output 0.5 
seconds or longer after 
operation. 

Ingress of foreign matter 

Loss of lubrication 

Sticking after long period of inactivity 

Leakage to exhaust port 
preventing output. 

Ingress of foreign matter 

Loss of lubrication 

Malfunction delaying exhaust. 

Ingress of foreign matter 

Table 4. 

 

10 Product Disposal 

This  product  shall  not  be  disposed  of  as  municipal  waste.  Check  your 
local regulations and guidelines to dispose this product correctly, in order 
to reduce the impact on human health and the environment. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11 Contacts 

Refer  to  www.smcworld.com  or  www.smc.eu  for  your  local 
distributor/importer. 

 

 