1.17-9
5 Port Pilot/Metal Seal
Body Ported
Series
VFS1000
Standard Specifications
Model
Compact and Large Flow
Capacity: 491N
l
/min
Small Power Consumption/
1.8W DC
Option Specifications
JIS Symbol
VFS1320-
D-01
VFS1120-
G-01
VFS1220-
E-01
VFS1120-
G-01-F
Configuration
Model
Port size
Effective area
(mm
2
) (N
l
/min)
Max. operating
cycle (CPM)
(1)
Response
time (ms)
(2)
Weight
(kgf)
(3)
2 position
3 position
Single
Double
Closed
centre
Exhaust
centre
Pressure
centre
VFS1120
VFS1220
VFS1320
VFS1420
VFS1520
VFS1130
VFS1230
VFS1330
VFS1430
VFS1530
9.0 (491)
9.0 (491)
7.2 (393)
9.0 (491)
8.8 (481)
1200
1200
600
600
600
15 or less
13 or less
20 or less
20 or less
20 or less
0.18
0.26
0.27
0.27
0.27
Note 1) According to JISB8375 (Once per 30 days) for the minumum operating frequency.
Note 2) According to JISB8375-1981. (The valve at supply pressure 0.5MPa.)
Note 3) In case of a grommet.
Note 4) The factors of "Note 1)" and "Note 2)" are achieved in controlled clean air.
1 8
1 8
1 8
1 8
1 8
Fuild
Air and inert gas
Max. operating pressure
1.0MPa
0.1MPa
0.15MPa
–10 to 60
o
C
(1)
Not required
(2)
Non-locking push style (Flush)
150/50m/s
2
(3)
Dust proof (protection level 0)
(4)
100V, 200V AC (50/60Hz), 24V DC
–15% to +10% rated voltage
5.6VA (50Hz), 5.0VA (60Hz)
3.4VA (2.1W)/50Hz, 2.3VA (1.5W)/60Hz
Inrush
Holding
2 position
3 position
DIN connector
Min. operating pressure
Ambient and fluid temperature
1.5MPa
Proof pressure
Lubrication
Pilot valve manual override
Shock/vibration resistance
Protection structure
Rated voltage
Allowance voltage
Class B or equivalent
(5)
Coil insulation
Apparent power
(Power consumption)
Electrical entry
1.8W
Power consumption DC
Note 1) Use dry air at low temperatures.
Note 2) Use turbine oil No.1 (ISO VG 32), if lubricated.
Note 3) Shock resistance: No malfunction on test using drop impact tester, to axis and right angle
directions of and armature main valve, each one time when energized and
deenergized. (Valve in the initial stage.)
Vibration resistance: No malfunction on test with 8.3 to 2000Hz, 1 sweep, to axis and right
angle directions of and armature main valve, each one time when
energized and de-energized. (Valve in the initial stage.)
Note 4) Based on JIS C0902. Note 5) Based on JIS C4003.
Valve
Solenoid
AC
2 position
3 position
Single
Closed centre
Double
Exhaust centre
Pressure centre
With indicator light and surge voltage suppressor
(1)
Manual override
Voltage
Foot bracket (with screw)
110 to 120V, 220V, 240V AC (50/60Hz)
Non-locking push style (Extended), Locking style (Slotted), Locking style (Lever)
12V, 100V DC
Note 1) No light for grommet but surge voltage suppressor (direct connecting lead wire) is
installed.
Option
Part No. AXT626-10A, VFS1120 (single) only
Manifold
Valve model
VFS1
30
Note) VFS1
30: Manifold only. Cannot be used as a single unit.
VFS1
20
Bar manifold (Common EXH. base side)
Bar manifold (Individual EXH)
Applicable manifold base (Pilot EXH)