background image

1.17-5

Series 

VFS 

Plug-in (with terminal)

•If removing the junction cover 

q

 on the sub-plate, 

there appears the plug-in style terminal block 

w

 

attached to the inside of sub-plate.

Light/Surge Voltage Suppressor/Electrical Entry

Single Unit

Light/Surge Voltage Suppressor

Wiring

In the case of voltage suppressor, surge volt-
age absorption element is attached to termi-
nal block on body area.

DIN connector

•Male pin terminal of DIN connector block board of 

solenoid valve and wires as shown below.

  Please  connect  each  valve  to  corresponding 

terminal block on connector.

How to Exchange

Solenoid valve

•Loosen set screw and take solenoid valve out 

vertically, otherwise it may cause damage to 
the solenoid valve. Never remove a valve at 
an angle.

•When mounting solenoid valve onto the base, 

plug  pin  ass’y  (base-side)  into  receptacle 
ass’y (body-side) vertically.

Pilot valve

•When  changing  the  rated  voltage,  electrical 

entry, etc., pilot valve ass’y can be exchanged 
easily  since  this  is  plug-in  style. Then,  when 
changing  the  rated  voltage  with  light/surge 
voltage suppressor, change of light/surge volt-
age suppressor substrate is also needed. So, 
order together with pilot valve assembly.

Light and surge voltage suppressor substrate part No.

VFS4000

VFS3000

VFS5000
VFS6000

VFS3000-10A-

VF4000-9A-

AXT627-7A-

VF4000-9A-

-

: Voltage

No polarity applies.

DIN connector (Wiring)

1
2
3

A side
B side

COM

Ground

AC and 100V DC or more.

24V DC or less

•Cabtire cable
    Applicable cable O. D.: ø6.8 to ø11.5
•Applicable terminal
    Applicable terminal on block board: 3 (kinds)
    1.25Y-3L, 1.25-3.5S, 1.25-4M
•Connector/Clamping torque
    Set screw 

6kgf-cm

    Terminal screw 

9kgf-cm

•Incorrect common (DIN connector No.3) 

causes damage on power side circut.

•The  following  marking  are  on  the  terminal  block. 

Connect with corresponding power side.

Terminal block
Marking

Solenoid A side Solenoid B side

A

B

•Applicable terminal
  VFS3000: 1.25-3, 1.25-3S, 1.25Y-3N, 
   

1.25Y-3S

  VFS4000: 1.25-3.5M, 1.25Y-3L, 1.25Y-3M
  VFS5000: 1.25-4, 1.25-4M
  VFS6000: 1.25-3.5M, 1.25Y-3L, 1.25-3M 
•No polarity applies.

AC  and  100V  DC  or 

24V DC or less

SOL

SOL

Single

Double

Single

Double

 No polarity

Series VFS3000, 4000, 5000, 6000

Base Mounted 

     Caution

Summary of Contents for VFS Series

Page 1: ...ht and surge voltage suppressor Plug in Conduit terminal FZ Non plug in Din connector DZ YZ Non locking push style Flush Non locking push style Extended Locking style Slotted Locking style Lever Base...

Page 2: ...ted VFS1000 VFS2000 VFS3000 Base Mounted Plug in VFS2000 VFS3000 VFS4000 VFS5000 Base Mounted Non Plug in VFS2000 VFS3000 VFS4000 VFS5000 Bar base Series VFS1000 2000 Plug in Non plug in 1 17 2 Manifo...

Page 3: ...Air release valve spacer Double check spacer SUP EXH block disk Manifold Options Manifold Optional Parts With control unit With exhaust cleaner 1 1 1 1 Serial interface unit Individual SUP spacer Indi...

Page 4: ...interior wiring is shown below Please connect with corresponding power side Changing Direction of DIN Connector Cable Entry AC and 100V DC 24V DC or less 24V DC or less Wiring In the case of DIN conne...

Page 5: ...g in style Then when changing the rated voltage with light surge voltage suppressor change of light surge volt age suppressor substrate is also needed So order together with pilot valve assembly Light...

Page 6: ...4 to 25 M5 28 to 50 Interface Regulator Specifications Model Applicable solenoid valve series Regulation Proof pressure Max operating pressure ARBF2000 ARBF3050 ARBF4050 ARBF5050 VFS2000 VFS3000 VFS40...

Page 7: ...ug q into the manifold base push the lever area of insert plug with thumb and plug it in its place in the receptacle housing r horizontally After plugging pull lead wire out a little bit to ensure tha...

Page 8: ...lug Assembly Option Wire Color Table GVVZS3000 21A 1S GVVZS3000 21A 2S Assembly part No Cable length 1m 3m GVVZS3000 21A 3S 5m GVVZS3000 21A 4S 8m GVVZS3000 21A 5S 20m Components Plug MIL standard D t...

Page 9: ...bient and fluid temperature 1 5MPa Proof pressure Lubrication Pilot valve manual override Shock vibration resistance Protection structure Rated voltage Allowance voltage Class B or equivalent 5 Coil i...

Page 10: ...ve class class I Mark VFS1 1 20 01 Configuration 1 2 position single 2 2 position double 3 3 position closed centre 4 3 position exhaust centre 5 3 position pressure centre Electrical entry D DIN conn...

Page 11: ...3 position closed centre exhaust centre pressure centre Replacement Parts Closed centre Exhaust centre Pressure centre No y t Description Material Stainless steel Part No Return spring Pilot valve ass...

Page 12: ...1 17 12 DIN Connector Grommet VFS1120 G Grommet terminal VFS1120 E EZ DIN connector VFS1120 D DZ With bracket F AXT626 10A Conduit terminal VFS1120 T TZ VFS1000 2 Position Single...

Page 13: ...FS1520 G Grommet terminal VFS1220 E EZ VFS1320 E EZ VFS1420 E EZ VFS1520 E EZ DIN connector VFS1220 D DZ VFS1320 D DZ VFS1420 D DZ VFS1520 D DZ Conduit terminal VFS1220 T TZ VFS1320 T TZ VFS1420 T TZ...

Page 14: ...ption Blank plate assembly VVFS1000 10A 1 With gasket screws How to Order Manifold Base VV5FS1 30 1 05 20 01 Series VFS1000 Manifold Symbol Symbol 1 Port specifications Porting specifications EA EB P...

Page 15: ...DIN connector D DZ General formula of weight Manifold M 0 049n 0 059 kg n Station 2 59 77 L L1 L2 3 83 101 4 107 125 5 131 149 6 155 173 7 179 197 8 203 221 9 227 245 10 251 269 Equation L1 24 X n 11...

Page 16: ...ctor D DZ General formula of weight Manifold M 0 079n 0 093 kg n Station D side 2 59 77 L L1 L2 3 83 101 4 107 125 5 131 149 6 155 173 7 179 197 8 203 221 9 227 245 10 251 269 Equation L1 24 X n 11 L2...

Reviews: