No. VF1000(V200)-TFM121**

 

 

Installation and Maintenance Manual 
5 port solenoid valve

 

Series VF1000/3000/5000

 

 

 

 

 

 

1 Safety Instructions 

This manual contains essential information for the protection of users and 
others from possible injury and/or equipment damage. 

• 

Read this manual before using the product, to ensure correct handling, 
and read the manuals of related apparatus before use. 

• 

Keep this manual in a safe place for future reference. 

• 

These instructions indicate the level of potential hazard by label of 
“Caution”, “Warning” or “Danger”, followed by important safety 
information which must be carefully followed. 

• 

To ensure safety of personnel and equipment the safety instructions in 
this manual and the product catalogue must be observed, along with 
other relevant safety practices. 

 

 

 Caution 

Indicates a hazard with a low level of risk, which if not 
avoided, could result in minor or moderate injury. 

 

 Warning 

Indicates a hazard with a medium level of risk, which 
if not avoided, could result in death or serious injury. 

 

 Danger 

Indicates a hazard with a high level of risk, which if 
not avoided, will result in death or serious injury. 

 
 
 
 

Warning 

• 

The compatibility of pneumatic equipment is the responsibility of the 
person who designs the pneumatic system or decides its specifications. 
Since the products specified here can be used in various operating 
conditions, their compatibility with the specific pneumatic system must 
be based on specifications or after analysis and/or tests to meet specific 
requirements. 

• 

Only trained personnel should operate pneumatically operated 
machinery and equipment. 

Compressed air can be dangerous if an operator is unfamiliar with it. 
Assembly, handling or repair of pneumatic systems should be performed 
by trained and experienced personnel. 

• 

Do not service machinery/equipment or attempt to remove 
components until safety is confirmed. 

1) Inspection and maintenance of machinery/equipment should only be 
performed after confirmation of safe locked-out control positions. 
2) When equipment is to be removed, confirm the safety process as 
mentioned above. Switch off air and electrical supplies and exhaust all 
residual compressed air in the system. 
3) Before machinery/equipment is re-started, ensure all safety measures 
to prevent sudden movement of cylinders etc. (Supply air into the 
system gradually to create back pressure, i.e. incorporate a soft-start 
valve). 

• 

Do not use this product outside of the specifications. Contact SMC 
if it is to be used in any of the following conditions: 

1) Conditions and environments beyond the given specifications, or if 
the product is to be used outdoors. 
2) Installations in conjunction with atomic energy, railway, air navigation, 
vehicles, medical equipment, food and beverage, recreation equipment, 
emergency stop circuits, press applications, or safety equipment. 
3) An application which has the possibility of having negative effects on 
people, property, or animals, requiring special safety analysis. 

 

Caution

 

• 

Ensure that the air supply system is filtered to 5 microns.

 

 

 
 
 

2 Specifications 

Refer to the operation manual for this product. 

2.1 Specifications 
Valve specifications 

Fluid 

Air 

2 position single/3 position 

0.15 to 0.7 MPa 

Standard 

2 position double 

0.1 to 0.7 MPa 

2 position single/3 position  

0.15 to 1.0 MPa 

Operating 
pressure 
range 

High 
pressure  

2 position double 

0.1 to 1.0 MPa 0.2 

Ambient and fluid temperature 

-10 ~ 50 °C (No freezing) 

Series 

VF1000 

VF3000 

VF5000 

2 position single / 
2 position double 

10 Hz 

10 Hz 

5 Hz 

Maximum operating 
frequency 

3 position  

3 Hz 

3 Hz 

Manual override 

Non-locking push type, Push turn 

locking slotted type, Push turn locking 

lever type 

Pilot exhaust method 

Individual exhaust. 

Common exhaust for main valve and 

pilot valve (except VF1000 series) 

Lubrication 

Not required 

Mounting position 

Unrestricted 

Impact / Vibration resistance 

300/50 m/s² 

(1)

Protection structure 

Dust proof (G,H,L,M : IP40) 

(D,Y,T : IP65*) 

Table 1 

Note) 

Impact resistance:

 No malfunction occurred when it was tested with a 

drop tester in the axial direction and at right angles to the main valve & 
armature; in both energised & de-energised states and for every time in 
each condition (Values at the initial period.) 

Vibration resistance:

 No malfunction occurred in a one-sweep test 

between 45 and 2000 Hz. Tests are performed at both energised and de-
energised states in the axial direction and at right angles to the main valve 
& armature. (Valves at the initial period.) 
*Based on IEC60529. Compliance to IP65 is limited to the common 

exhaust option. 

 
 
 
 
 

Solenoid Specifications

 

Grommet (G),(H), 

L plug connector (L), 

M plug connector (M) 

DIN terminal (D),  
DIN (EN175301-803)  
terminal (Y),  
Conduit terminal (T) 

Electrical entry 

G,H,L,M 

D,Y,T 

DC  

24,12 V 

Coil rated 
voltage 

AC (50/60 Hz) 

 100,110,200,220,240 

Allowable voltage fluctuation 

±

10% rated voltage

1,2,3

Standard 

1.5 W 

(With indicator light: 1.55 W)

1.5 W 

(With indicator light: 1.75 W)

DC 

Power saving 
type  

0.55 W 

(With indicator light only)

 

0.75 W 

(With indicator light only)

 

100V 
110V [115 V] 
200V 
220V [230 V] 

Power

  

Con

sumptio

n  

 

AC 

240V 

 

1.55 VA 

(With indicator light: 1.7 VA)

Surge voltage suppressor 

Diode 

(Non-polar type is varistor) 

Indicator light 

LED 

LED 

(Neon bulb when AC) 

Table 2 

1) In common between 110 VAC and 115 VAC, and between 220 VAC and 

230 VAC. 

2) For 115 VAC and 230 VAC, the allowable voltage is -15% ~ +5% of 
rated voltage. 
3) S, Z and T type (with power saving circuit), should be used with the 
following allowable voltage fluctuation range due to a voltage drop caused 
by the internal circuit. 
24 VDC: -7% to +10%            
12 VDC: -4% to +10% 

 
 
 

 
 
 
 
 

2 Specifications (continued)

 

3 Installation (Continued

alves, tighten as follows: 

C fitting, etc. 

Note

r the 

   

) W

2) T

 the proper tightening torques shown below. 

m) 

2.2 Symbol 
Body ported 

 

Single 

Double 

VF1000 

 

 
 

 
 
 

VF3000 
VF5000 

 

 
 

 
 
 
 
 

 
Base mounted 

 

Single 

Double 

VF3000 
VF5000 

 

 
 

 
 
 
 
 

 
Body ported / Base mounted 

 

Closed centre 

Exhaust centre 

Pressure centre 

VF3000 
VF5000

 

 
 
 
 
 

 

 

Figure 1 

 
 
 
 

3 Installation 

3.1 Installation 

Warning 

• 

Do not install the product unless the safety instructions have been read 
and understood. 

 

3.2 Environment 

Warning 

• 

Do not use in an environment where corrosive gases, chemicals, salt 
water or steam are present. 

• 

Do not use in an explosive atmosphere. 

• 

Do not expose to direct sunlight. Use a suitable protective cover. 

• 

Do not install in a location subject to vibration or impact. Check the 
product specifications. 

• 

Do not mount in a location exposed to radiant heat. 

• 

If it is used in an atmosphere where there is possible contact with water 
droplets, oil, weld spatter, etc., exercise preventative measures. 

• 

When the solenoid valve is mounted in a control panel or its energised 
for a long time, make sure that the ambient temperature is within the 
specification of the valve. 

 

3.3 Piping 

Caution 

• 

Before piping make sure to clean up chips, cutting oil, dust etc. 

• 

When installing piping or fittings, ensure sealant material does not enter 
inside the port. When using seal tape, leave 1 thread exposed on the 
end of the pipe/fitting. 

• 

Tighten fittings according to appropriate tightening torque. 

 
 
 
 
 

 
 
                   

Figure 2 

3.4  Connection of fittings 

 When screwing fittings into v
(1) Follow the procedures below when installing an SM
1) M5  
After tightening the fitting by hand, use a wrench to tighten the fitting an 

additional approximately 1/6 turn. However, if miniature fittings are 
used, tighten an additional 1/4 turn with a tightening tool after 
tightening by hand. 

) If tightened excessively, the thread of the product may break o

gasket may deform. If tightened insufficiently, the thread of the 
product may become loose. In either case, air leakage can occur. 

hen fittings other than SMC fittings are used, follow the instructions of 

(2

the respective fitting manufacturer. 

 

hreads 

 
  Fasten with

Connection thread 

Tightening torque (N

1/8 

7 to 9 

1/4 

12 to 14 

3/8 

22 to 24 

1/2 

28 to 30 

Table 3 

 

.5  Connection of piping to products 

uction manual to avoid mistakes 

.6  Precautions on Design  <DC> 

With light/surge voltage suppressor (

Z) 

 

3

When piping to a product, refer to its instr
regarding the supply port, etc. 

 
 
 
 
 
 
 
 
 

3

 Polar type 

oltage suppressor  ( S) 

With surge v

Grommet/L,M plug connecter 

 

 

 
 
 
 
 

With light/surge voltage suppressor (

Z)  DIN terminal/Conduit terminal 

 
 
 
 
 
 

Non-polar type 

 suppressor (

R) 

With light/surge voltage suppressor (

U) 

With surge voltage

Grommet/L,M plug connecter 

 

 

 
 
 
 
 

With light/surge voltage suppressor (

U)   DIN terminal/Conduit terminal 

 
 
 
 
 
 
 

Table 4 

• 

Please connect in accordance with 

olarity indication. (The non-polar type 

• 

• 

the +,- p

can be used with the connections made either way.) 
Please use caution regarding the allowable voltage fluctuation because there is 
approximately a 1 V drop for a valve with polarity protection (For details, refer to 
the solenoid specifications for the valve.) 
When wiring is done at the factory, positive (+) is red and negative (-) is black. 