8
®
Series SYJ3000
Valve Specifications
SYJ312
SYJ322
SYJ332
SYJ342
SYJ352
SYJ314
SYJ324
SYJ334
SYJ344
SYJ354
SYJ313
SYJ323
SYJ333
SYJ343
SYJ353
M3 0.5
M5 0.8
_
0.9
(0.05)
1.8
(0.1)
Note1)
1.2
(0.067)
Grommet
33
47
50
59(33)
73(47)
76(50)
33
47
50
35
51
54
61(35)
77(51)
80(54)
35
51
54
Model
Fluid
Type of actuation
Port size
Effective
area
mm
2
(Cv)
Weight g
Note 2, 3)
L type, M type
plug connector
Specifications
Valve model
5 Port
Body ported type
5 Port
Base mounted type
(With sub-plate)
4 Port
Base mounted type
For manifold
use only
Operating pressure range
PSI (MPa)
Ambient and fluid temperature (
°
F)
Response time (ms)
Max. operating frequency (Hz)
Manual override
Pilot exhaust
Lubrication
Mounting position
Impact / Vibration resistance (m/s
2
)
Protection structure
Solenoid Specifications
Electrical entry
Coil rated voltage (V)
Allowable voltage
Power consumption (W)
Note4)
Apparent power (VA)
Surge voltage suppressor
Indicator light
Grommet(G)/(H), L type plug connector(L),
M type plug connector(M)
24,12,6,5,3
100, 110 , 200, 220
±
10% rated voltage
0.5(With light:0.55)
0.9(With light:1.0)
1.0(With light:1.1)
[1.1(With light:1.2)]
1.8(With light:1.9)
1.9(With light:2.0)
[2.2(With light:2.3)]
Diode
LED
( )
Note1) In case of M5 and mounted on manifold base.
Note2) ( ):Without sub-plate.
Note3) For DC voltages. For AC voltages add 1g to the weight of the single solenoid and 2g to the weight of the
double solenoid and 3 position types.
2 position
3 position
2 position
3 position
2 position
3 position
Single
Double
Closed center
Exhaust center
Pressure center
Single
Double
Closed center
Exhaust center
Pressure center
Single
Double
Closed center
Exhaust center
Pressure center
2 position single
2 position double
3 position
2 position single,double
3 position
2 position single,double
3 position
Air
22 ~ 100 (0.15 to 0.7)
15 ~ 100 (0.1 to 0.7)
30 ~ 100 (0.2 to 0.7)
Max.122
15 or less
30 or less
10
3
Non-locking push type,Push-locking slotted type
Individual pilot exhaust type, common exhaust(pilot and main valve)type
Not required
Free
150/30
Dust proof
Can be used for 115VAC in common.
Can be used for 230VAC in common.
Note 4) At rated voltage
DC
AC50/60Hz
DC
100V
110V
[115V]
200V
220V
[230V]
AC
B
P R
A
B
P R
A
B
P R
A
B
P R
A
B
P R
A
2 Position single
2 Position double
B
P
R
R
A
B
P
R
R
A
B
P
R
R
A
B
P
R
R
A
B
P
R
R
A
2 Position single
2 Position double
3 Position closed center
3 Position exhaust center
3 Position pressure center
3 Position pressure center
3 Position exhaust center
3 Position closed center
JIS Symbol
5 Port
4 Port(manifold)
Body ported type
Base mounted type
JIS Symbol
8
®
8
®
8
®
8
®
8
®