background image

Doc. no.SX90***-OMY0004 

 

 

 

 

 

 

 

 
 

PRODUCT NAME

 

 

Low Profile 2/3-Port Solenoid Valve 

 

MODEL / Series / Product Number

 

 

SX90/090 Series 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for SX090 Series

Page 1: ...Doc no SX90 OMY0004 PRODUCT NAME Low Profile 2 3 Port Solenoid Valve MODEL Series Product Number SX90 090 Series...

Page 2: ...Instrucrions P4 Selection P4 Mounting P5 Piping P5 Wrining P6 Air Supply P6 Operating Enviroment P6 P7 Maintenance P7 How to order P8 Specifications P8 Dimensions P9 Specific Product Precautions P9 T...

Page 3: ...failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The assembl...

Page 4: ...the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded from this...

Page 5: ...hing operation with the PWM control circuit inside the valve after the rated power has been applied for several tens of ms to reduce the power consump tion The problems shown below may occur in this t...

Page 6: ...Mounting orientation The mounting orientation is universal 7 Initial lubrication of main valve The main valve is already applied initial lubricant Grease Caution 5 Warning 1 Operation manual Install...

Page 7: ...4 Use clean ai Do not use compressed air that contains chemicals synthetic oils that include organic solvents salt corrosive gases etc as it can cause damage or malfunction Air Supply Caution 1 When e...

Page 8: ...and electric power and exhaust all air pressure from the system using the residual pressure release function For the 3 position closed center or double check valve types exhaust the residual pressure...

Page 9: ...VDC Rated 35 0 8 W Allowable voltage fluctuation 5 10 of rated voltage 0 to 10 Type of coil insulation Class B w e r SX9 1 5 G SX090 5 G q 2 port valve 3 port valve 1 For use with fluids other than ai...

Page 10: ...duration Do not touch the valve by hand directly When there is such a dangerous case to be touched by hands directly install a protective cover 3 When using the solenoid valves on a manifold note tha...

Page 11: ...oltage Incorrect selection of voltage Directly exposed to water Damage or deformation of external force Foreign matter got stuck in the valve valve becomes sticky Damage or deformation of external for...

Page 12: ...ve 8 Replace the valve Protect the valve to prevent it from being exposed to water 9 Replace the valve Please do not apply force to the coil and frame when installing the piping and valves 10 Replace...

Page 13: ...u Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL https www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manufacture...

Reviews: