2/

3-Port Solenoid Valves

 

Precautions 4

Be sure to read this before handling products.

-7-

Caution

1. Temperature of ambient environment

Use  the  valve  within  the  range  of  the  ambient  temperature

specification  of  each  valve.  In  addition,  pay  attention  when

using  the  valve  in  environments  where  the  temperature

changes drastically.

2. Humidity of ambient environment

When using the valve in environments with low humidity, take

measures to prevent static.

If the humidity rises, take measures to prevent the adhesion

of water droplets on the valve.

Operating Environment

 

Maintenance

Warning

1. Perform  maintenance  and  inspection  ac-

cording  to  the  procedures  indicated  in  the

operation manual.

If  handled  improperly,  human  injury  and/or  malfunction  or

damage of machinery and equipment may occur.

2. Removal of equipment, and supply/exhaust of

compressed air

Before components are removed, first confirm that measures

are  in  place  to  prevent  workpieces  from  dropping,  run-away

equipment,  etc.  Then,  cut  off  the  supply  air  and  electric

power, and exhaust all air pressure from the system using the

residual pressure release function.

For  the  3-position  closed  center  or  double  check  valve  types,

exhaust  the  residual  pressure  between  the  valve  and  the

cylinder.

When the equipment is operated after remounting or replace-

ment, first confirm that measures are in place to prevent the

lurching of actuators, etc. Then, confirm that the equipment is

operating normally.

In particular, when a 2-position double solenoid valve is used,

releasing residual pressure rapidly may cause the spool valve

to  malfunction,  depending  on  the  piping  conditions,  or  the

connected actuator to operate.

3. Low-frequency operation

Valves  should  be  operated  at  least  once  every  30  days  to

prevent malfunction. (Use caution regarding the air supply.)

4. Manual override

When  a  manual  override  is  operated,  connected  equipment

will be actuated.

Operate only after safety is confirmed.

5. If  the  volume  of  air  leakage  increases  or  the

valve  does  not  operate  normally,  do  not  use

the valve.

Perform periodic maintenance on the valve to

confirm the operating condition and check for

any air leakage.

Caution

1. Drain flushing

Remove drainage from the air filters regularly.

Summary of Contents for SX090 Series

Page 1: ...Doc no SX90 OMY0004 PRODUCT NAME Low Profile 2 3 Port Solenoid Valve MODEL Series Product Number SX90 090 Series...

Page 2: ...Instrucrions P4 Selection P4 Mounting P5 Piping P5 Wrining P6 Air Supply P6 Operating Enviroment P6 P7 Maintenance P7 How to order P8 Specifications P8 Dimensions P9 Specific Product Precautions P9 T...

Page 3: ...failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The assembl...

Page 4: ...the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded from this...

Page 5: ...hing operation with the PWM control circuit inside the valve after the rated power has been applied for several tens of ms to reduce the power consump tion The problems shown below may occur in this t...

Page 6: ...Mounting orientation The mounting orientation is universal 7 Initial lubrication of main valve The main valve is already applied initial lubricant Grease Caution 5 Warning 1 Operation manual Install...

Page 7: ...4 Use clean ai Do not use compressed air that contains chemicals synthetic oils that include organic solvents salt corrosive gases etc as it can cause damage or malfunction Air Supply Caution 1 When e...

Page 8: ...and electric power and exhaust all air pressure from the system using the residual pressure release function For the 3 position closed center or double check valve types exhaust the residual pressure...

Page 9: ...VDC Rated 35 0 8 W Allowable voltage fluctuation 5 10 of rated voltage 0 to 10 Type of coil insulation Class B w e r SX9 1 5 G SX090 5 G q 2 port valve 3 port valve 1 For use with fluids other than ai...

Page 10: ...duration Do not touch the valve by hand directly When there is such a dangerous case to be touched by hands directly install a protective cover 3 When using the solenoid valves on a manifold note tha...

Page 11: ...oltage Incorrect selection of voltage Directly exposed to water Damage or deformation of external force Foreign matter got stuck in the valve valve becomes sticky Damage or deformation of external for...

Page 12: ...ve 8 Replace the valve Protect the valve to prevent it from being exposed to water 9 Replace the valve Please do not apply force to the coil and frame when installing the piping and valves 10 Replace...

Page 13: ...u Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL https www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manufacture...

Reviews: