background image

Pressure Sensor for General Fluids  PSE57

 

Series

3-Screen Display

Sensor Monitor  PSE300AC 

Series

Withstand voltage

Rated pressure range

500 VAC

<Twice that of the PSE560>

Materials of Parts in Contact with Fluid

Piping port

C3604 + Nickel plating

Pressure sensor

Al

2

O

3

 

(Alumina 96%)

Square ring

FKM

Pressure Sensor/

3-Screen Display

Sensor Monitor

Remote Type

0 to 1 MPa

0 to 2 MPa

−100 to 100 kPa

0 to 5 MPa

0 to 500 kPa

0 to 10 MPa

Measured value (Current pressure value)

Label (Display item), 
Set value (Threshold value)

Main screen

Sub screen

Visualization of Settings

Set value (Threshold value)

Hysteresis value

Delay time

Peak value

Bottom value

New

New

It is possible to
change the settings
while checking
the measured value.

CAT.ES100-119A

PSE57

/PSE300AC

 Series

IP65

RoHS

a

Summary of Contents for PSE300AC

Page 1: ...e ring FKM Pressure Sensor 3 Screen Display Sensor Monitor Remote Type 0 to 1 MPa 0 to 2 MPa 100 to 100 kPa 0 to 5 MPa 0 to 500 kPa 0 to 10 MPa Measured value Current pressure value Label Display item...

Page 2: ...500 kPa PSE575 576 577 2 MPa 5 MPa 10 MPa For General Fluids Variations PSE56 Series Wetted parts Stainless steel 316L IP65 Oil free Single diaphragm construction Compact Pneumatic Pressure Sensor Lo...

Page 3: ...et value Threshold value Reverse output Set value Threshold value Normal output Hi side Set value Threshold value Hysteresis Set hysteresis value Reverse output Lo side Set value Threshold value Rever...

Page 4: ...Output Voltage output 1 to 5 V Current output 4 to 20 mA Impedance Output impedance Approx 1 k Maximum load impedance 500 or less at 24 VDC 100 or less at 12 VDC Nil Voltage output type 1 to 5 V 28 C...

Page 5: ...l 304 Lead wire and M12 connector ZS 37 A 1 to 5 VDC 4 to 20 mA DC mm Part no D E F G H I ZS 31 X188 20 9 R1 8 Rc1 8 14 1 5 ZS 31 X175 29 13 R1 4 Rc1 4 17 1 6 Internal Circuits and Wiring Examples PSE...

Page 6: ...voltage protection up to a voltage of 26 4 VDC Display Unit 3 MPa kPa Pa kgf cm2 bar mbar psi inHg mmHg mmH2O Display type LCD Number of screens 3 screen display Main screen Sub screen x 2 Display co...

Page 7: ...ng Examples Setting of NPN open collector 2 outputs Pressure sensor 3 wire type Setting of NPN open collector 2 outputs Pressure sensor 2 wire type Setting of PNP open collector 2 outputs Pressure sen...

Page 8: ...This eliminates wide variations of the indicated value Suction Verification Formula for Obtaining the Set Value This function constantly detects and updates the maximum minimum pressure when the powe...

Page 9: ...ple setting mode or F1 A large bore cylinder or ejector consumes a large volume of air during operation and may experience a temporary drop in the supply pressure This function prevents the detection...

Page 10: ...Straight 3 m ZS 37 B Right angle 3 m PCA 1557743 Assembly type connector ZS 31 C Right angle 5 m PLC PCA 1557743 Assembly type connector Lead wire and M12 connector Assembly type connector Set part no...

Page 11: ...ironments outside of the given specifications or use outdoors or in a place exposed to direct sunlight 2 Installation on equipment in conjunction with atomic energy railways air navigation space shipp...

Reviews: