3-Screen Display
Sensor Monitor
PSE300AC
Series
*
1 The PSE5
1 (vacuum pressure), PSE5
2 (low pressure), and PSE5
3 (compound pressure) will have different setting and display resolution when the unit is set to MPa.
Display unit
Smallest settable increment
Rated pressure
range
MPa
*
1
kPa
Pa
kgf/cm
2
bar
mbar
psi
inHg
mmHg
mmH
2
O
Applicab
le SMC pressure sensor
PSE550
0 to 2 kPa
0.001
1
0.01
0.001
0.1
PSE531
PSE541
PSE561
0 to −101 kPa
0.001
0.1
0.001
0.001
0.01
0.1
1
PSE533
PSE543
PSE563
PSE573
−100 to 100 kPa
0.001
0.1
0.001
0.001
0.02
0.1
1
PSE532
0 to 100 kPa
0.001
0.1
0.001
0.001
0.01
PSE564
PSE574
0 to 500 kPa
0.001
1
0.01
0.01
0.1
PSE530
PSE540
PSE560
PSE570
0 to 1 MPa
0.001
1
0.01
0.01
0.1
PSE575
0 to 2 MPa
0.001
1
0.01
0.01
0.2
PSE576
0 to 5 MPa
0.01
0.1
0.1
1
PSE577
0 to 10 MPa
0.01
0.1
0.1
1
Pressure
↑
Set value P_1
Momentary change
t (ms)
t (ms)
Time
→
Time
→
Time
→
<Delay time>
<Delay time>
Switch output
operation under
normal conditions
ON
OFF
Switch output
operation when
anti-chattering
function is on
ON
OFF
H_1
G
Anti-chattering function (Simple setting mode or F1)
A large bore cylinder or ejector consumes a large volume of air during operation and may experience a temporary drop in the supply pressure.
This function prevents the detection of such temporary drops in the supply pressure as errors by changing the delay time setting.
<Principle>
This function averages pressure values measured during the response time set by the user and then
compares the average pressure value with the pressure set point value to output the result on the switch.
H
Unit selection function (F0)
Display units can be switched with this function.
I
Power-saving mode (F80)
Power-saving mode can be selected.
It shifts to power-saving mode automatically when there is no button operation for 30 seconds.
The product is set to normal mode (Power-saving mode is OFF) at the time factory shipment.
(When in power-saving mode, [ECo] will flash in the sub screen and the operation light will be ON (only when the switch is ON).)
J
Setting of secret code (F81)
Users can select whether a secret code must be entered to release the key lock.
At the time of factory shipment, it is set so that a secret code is not required.
Available delay time settings
1 ms or less, 20 ms, 100 ms, 500 ms, 1000 ms, 2000 ms, 5000 ms
Function Details
8