-30-
No.PF
※※
-OMU0007-B
●
[F 2] Setting of OUT2
Item
Explanation
Default setting
Output mode
Either hysteresis mode, window comparator mode, accumulated
output, accumulated pulse, error output or switch output off can
be selected.
Hysteresis mode
Reversed output
Selects which type of switch output is used, normal or reversed.
Normal output
Flow setting
Sets the ON and OFF point of the switch output.
1500 L/min
Hysteresis
Appropriate setting of the hysteresis will prevent the switch
output from chattering.
150 L/min
Delay time
Delay time of the switch output can be selected.
0.00 s
Display colour
Select the display colour.
Output ON: Green
Output OFF: Red
(Linked to OUT1)
●
Other parameter settings
Item
Page
Default setting
[F 3] Digital filter setting
0.00 s
[F 5] FUNC terminal function setting
2
Analogue output: 1 to 5 V/4 to 20 mA
External input: Accumulated value reset
[F10] Sub display setting
dEF
[F14] Display with zero cut-off setting
1.0%F.S.
[F30] Accumulated value hold setting
OFF
[F80] Power saving mode
OFF
[F81] Security code
OFF
[F90] Setting of all functions
OFF
[F96] Sensor input/External input signal status display
No configurable items
[F97] Copy master setting
No configurable items
[F98] Output check
Normal output
[F99] Reset to default settings
OFF
2: This function is available for models with analogue output.