-52-
No.PF
※※
-OMU0007-B
■
[F80] Power saving mode
Power saving mode can be selected.
When selected, if no buttons are pressed for 30 seconds, the product will shift to power saving mode.
<Operation>
Press the
or
button in function selection mode to display [F80].
Press the
button.
Move on to power saving mode.
Power saving mode
Press the
or
button to select the power saving mode.
Press the
button to set.
Return to function selection mode.
[F80] Power saving mode completed
In power saving mode, when buttons are pressed the display is normal, but if no buttons are pressed for
30 seconds, it will revert to power saving mode (Power saving is only available in measurement mode).
During power saving mode, [ECo] will flash in
the sub display and the operation LED is ON
(when the switch is ON).
: There may be a difference in the displayed value between the connected flow switch and the flow monitor.
When the flow switch display is used, it is recommended to set the flow switch display OFF mode.