-43-
No.PF
※※
-OMU0007-B
■
[F 3] Digital filter setting
The digital filter can be selected to filter the flow measurement (0 to 30 sec.).
Output chattering or display flicker in measurement mode can be reduced by setting the digital filter.
<Operation>
Press the
or
button in function selection mode to display [F 3].
Press the
button.
Move on to digital filter setting.
Digital filter setting
Press the
or
button to select the digital filter.
Digital filter set range: 0.00 to 30.00 [S]
Press the
button to set.
Return to function selection mode.
[F 3] Digital filter setting completed
1: Each set value is a guideline for 90% response time.
2: The Switch output and flow display/analogue output are affected.
When only the switch output needs to be filtered, select and adjust the delay time setting. (page
and