Master
Slaves
(Max. 10 units)
1 unit
2 units
·········
10 units
DC (+)
OUT1
OUT2
FUNC
DC (−)
Gray (Copy wire)
DC (+)
OUT1
OUT2
FUNC
DC (−)
DC (+)
OUT1
OUT2
FUNC
DC (−)
DC (+)
OUT1
OUT2
FUNC
DC (−)
Power supply
Slave monitors
1 unit
2 units
n units
(Max. 10 units)
Master monitor
Blue
Brown
Blue
Brown
Gray (Copy wire)
Blue
Brown
Gray (Copy wire)
Blue
Brown
Gray (Copy wire)
1) Wire as shown in the figure on the left.
2) Select the slave monitor which is to be the master, and
change it into a master using the buttons. (In the default
setting, all flow monitors are set as slaves.)
3) Press the e button on the master monitor to start
copying.
W
Copy function
The settings of the master monitor can be copied to the slave monitors,
reducing setting labor and minimizing the risk of setting mistakes.
The set value can be copied to up to 10 flow monitors simultaneously.
(Maximum transmission distance: 4 m)
W
Selection of power saving mode
The power saving mode can be selected.
With this function, if no buttons are pressed for 30 s, it shifts to power saving mode.
At the time of shipment from the factory, the product is set to the normal mode (the power saving mode is turned off).
(During power saving mode, [ECo] will flash in the sub screen and the operation light will be ON (only when the switch is ON).)
*
There may be a difference in the displayed value on the connected flow switch and the flow monitor. When the flow monitor display is being
used, it is recommended to set the flow switch display to OFF mode.