Min. value of the
rated flow range
Voltage output (1 to 5 V)/
Current output (4 to 20 mA)
Max. value of the
rated flow range
A
B
0
Flow
Output
Voltage output (0 to 10 V)
D
C
0
Min. value of the
rated flow range
Max. value of the
rated flow range
Flow
Output
Analog Output
Flow Range
Model
Min. value of the
rated flow range
*
4
Max. value of the
rated flow range
PF3A701H
(
-L
)
10 L/min
1000 L/min
PF3A702H
(
-L
)
20 L/min
2000 L/min
PF3A703H
(
-L
)
30 L/min
3000 L/min
PF3A706H
(
-L
)
60 L/min
6000 L/min
PF3A712H
(
-L
)
120 L/min
12000 L/min
Model
Flow range
0
L/min 1000
L/min 3000
L/min 6000
L/min 12000
L/min
PF3A701H
(
-L
)
PF3A801H-L
PF3A702H
(
-L
)
PF3A802H-L
PF3A703H
(
-L
)
PF3A706H
(
-L
)
PF3A712H
(
-L
)
30 L/min
30 L/min
60 L/min
60 L/min
120 L/min
120 L/min
0 L/min
0 L/min
0 L/min
3000 L/min
6000 L/min
3150 L/min
6300 L/min
3150 L/min
6300 L/min
12000 L/min
12600 L/min
12600 L/min
10 L/min
10 L/min
20 L/min
20 L/min
0 L/min
0 L/min
1000 L/min
2000 L/min
1050 L/min
2100 L/min
1050 L/min
2100 L/min
Rated flow range
Set point range
Display range
Flow/Analog Output
*
1 Analog output accuracy is within
±
3% F.S.
*
2 A and C will change according to the setting of the zero cut-
off function.
*
3 The analog output current from the connected equipment
should be 20
μ
A or less when selecting 0 to 10 V. When
more than 20
μ
A current flows, it is possible that the accura-
cy is not satisfied below 0.5 V.
*
4 The minimum value of the rated flow range will change
according to the setting of the zero cut-off function.
0 L/min
A
*
2
B
Voltage output (1 to 5 V)
*
1
1 V
1.04 V
5 V
Current output
*
1
4 mA
4.16 mA
20 mA
0 L/min
C
*
2
D
Voltage output (0 to 10 V)
*
1
*
3
0 V
0.1 V
10 V
23
PF3A
w
H(-L)
Series