W
Zero-clear function (PF3A8
w
H-L series only)
This function clears and resets the zero value on the display of the
measured pressure. The indicated value can be adjusted within
±
7%
F.S. of the pressure at the time of shipment from the factory.
W
Display fine adjustment function (PF3A8
w
H-L series only)
Fine adjustment of the indicated value of the pressure sensor can be
made within the range of
±
5 % of the read value. (This eliminates
wide variations of the indicated value.)
W
Measurement display setting (PF3A8
w
H-L series only)
Display/hide the measured accumulated flow rate, pressure, and temperature.
Normal display
Accumulated flow display OFF
Pressure display OFF
Displays the instantaneous flow, accumulated
flow, pressure, and temperature
Displays items other than the accumulated flow
Displays items other than the pressure
Temperature display OFF
Accumulated flow, pressure, and temperature display OFF
Displays items other than the temperature
The accumulated flow display changes from 6 digits to 9 digits.
Displays the instantaneous flow
39
PF3A
w
H(-L)