2-colour LCD display
2-colour LED
display
2-colour LCD
display
Monitor unit:
2-colour LCD display
Monitor unit:
3-colour LCD display
Flow Switch Variations / Basic Performance Table
PF2A
PFMV
PFMB
∗
The monitor unit values are for the PFG300 and PFMV3.
12 to 24 VDC
±
10 %
18 to 30 VDC
±
10 %
PFMC7(-L)
24 VDC
±
10 %
PFMV3
p.
9
p.
18
PFG300
PFG300
PF2M7(-L)
12 to 24 VDC
±
10 %
18 to 30 VDC
±
10 %
PF2M7
PF2M7-L
PFMC
PFMC-L
18 to 30 VDC
±
10 %
PF3A7
H
PF3A7
H-L
0.01 to 1
0.02 to 2
0.05 to 5
0.1 to 10
0.3 to 25
0.5 to 50
1 to 100
Fluid
Series
Setting
Enclosure
Display
Output
Hysteresis
Repeatability
Power supply
voltage
Rated flow range
[l/min]
Temperature characteristics
(25 °C standard)
LED display
3-colour LCD display
3-colour LCD display
NPN/PNP
open collector
Accumulated pulse output
Analogue voltage output
Analogue current output
NPN/PNP
open collector
Accumulated pulse output
Analogue voltage output
Analogue current output
NPN/PNP
open collector
Accumulated pulse output
NPN/PNP
open collector
Analogue voltage output
Analogue current output
NPN/PNP
open collector
Accumulated pulse output
Analogue voltage output
Analogue current output
NPN/PNP
open collector
Accumulated pulse output
Analogue voltage output
Analogue current output
Hysteresis mode: Variable
Window comparator mode:
Variable
Hysteresis mode: Variable
Window comparator mode:
Variable
Hysteresis mode: Variable
Window comparator mode:
Variable
Hysteresis mode: Variable
Window comparator mode:
Fixed (3 digits)
Hysteresis mode: Variable
Window comparator mode:
Variable
Hysteresis mode: Variable
Window comparator mode:
Variable
±
1 % F.S.
(Fluid: Dry air)
±
1 % F.S.
(PF2A7
0)
±
2 % F.S.
(PF2A7
1)
±
2 % F.S.
(Fluid: Dry air)
Analogue output:
±
5 % F.S.
Monitor unit:
±
0.1 % F.S.
Analogue output:
±
0.3 % F.S.
±
1 % F.S.
(Fluid: Dry air)
Monitor unit:
±
0.1 % F.S.
±
1 digit
±
1 % F.S.
Monitor unit:
±
0.1 % F.S.
±
1 digit
Monitor unit:
±
0.1 % F.S.
±
1 digit
±
2 % F.S.
(15 to 35 °C)
±
5 % F.S.
(0 to 50 °C)
±
3 % F.S. (15 to 35 °C)
±
5 % F.S. (0 to 50 °C)
±
2 % F.S.
(15 to 35 °C)
±
5 % F.S.
(0 to 50 °C)
Monitor unit:
±
0.5 % F.S.
(0 to 50 °C)
±
2 % F.S.
(15 to 35 °C)
±
5 % F.S.
(0 to 50 °C)
Monitor unit:
±
0.5 % F.S.
(0 to 50 °C)
±
5 % F.S.
(0 to 50 °C)
Monitor unit:
±
0.5 % F.S.
(0 to 50 °C)
Monitor unit:
±
0.5 % F.S.
(0 to 50 °C)
12 to 24 VDC
±
10 %
12 to 24 VDC
±
10 %
12 to 24 VDC
±
10 %
1 to 10
5 to 50
10 to 100
20 to 200
50 to 500
2 to 200
5 to 500
10 to 1000
20 to 2000
5 to 500
10 to 1000
20 to 2000
30 to 3000
60 to 6000
120 to 12000
Digital
Digital
Digital
Digital
Digital
Digital
Dry air,
N
2
, Ar, CO
2
Air, N
2
Dry air, N
2
Dry air, N
2
Dry air, N
2
Air, N
2
IP40
IP40
IP65
IP40
IP65
[
Monitor unit:
IP40]
IP65
[
Monitor unit:
IP40]
±
3 % F.S.
±
1 digit
(15 to 35 °C)
±
5 % F.S.
±
1 digit
(0 to 50 °C)
±
1 % F.S.
±
1 digit
(Fluid: Dry air)
0 to 0.5
0 to 1
0 to 3
ïWR
ïWR
ïWR
21.6 to 30 VDC
PF3A701/
702H-L
PF3A7
H(-L)
PFG300
6
Summary of Contents for PF2A Series