Min. value of the
rated flow range
Voltage output (1 to 5 V)/
Current output (4 to 20 mA)
Max. value of the
rated flow range
A
B
0
Flow
Output
Min. value of the
rated flow range
Voltage output (0 to 10 V)
Max. value of the
rated flow range
D
C
Flow
0
∗
PFMC7-L only
Output
Pressure loss [kPa]
Flow [l/min]
0
10
20
30
40
50
0
100
200
300
400
500
Supply pressure
200 kPa
Supply pressure
400 kPa
Pressure loss [kPa]
Flow [l/min]
0
10
20
30
40
50
0
400
800
1200
1600
2000
Supply pressure
200 kPa
Supply pressure
400 kPa
Pressure loss [kPa]
Flow [l/min]
0
10
20
30
40
50
0
200
400
600
800
1000
Supply pressure
200 kPa
Supply pressure
400 kPa
OUT
IN
Straight
piping length
10
9
8
7
6
5
4
3
2
1
0
±
0
±
1
±
2
±
3
±
4
±
5
±
6
Accuracy [% F.S.]
Straight piping length [cm]
Model
Min. value of the rated flow range Max. value of the rated flow range
PFMC7501(-L)
5 l/min
500 l/min
PFMC7102(-L)
10 l/min
1000 l/min
PFMC7202(-L)
20 l/min
2000 l/min
Flow/Analogue Output
∗
1 Analogue output accuracy is within
±
3 % F.S.
∗
2 A and C will change according to the setting of the zero cut function.
∗
3 The analogue output current from the connected equipment
should be 2 0
μ
A or less when selecting 0 to 1 0 V. When more
than 2 0
μ
A current fl ows, it is possible that the accuracy is not
satisfi ed below 0.5 V.
∗
The minimum value of the rated flow range will change
according to the setting of the zero cut function.
0 l/min
A
∗
2
B
Voltage output (1 to 5 V)
∗
1
1 V
1.04 V
5 V
Current output
∗
1
4 mA
4.16 mA
20 mA
0 l/min
C
∗
2
D
Voltage output (0 to 10 V)
∗
1, 3
0 V
0.1 V
10 V
Rated fl ow range
Set point range
Display range
Pressure Loss (Reference Data)
PFMC7501(-L) (for 500 l/min)
PFMC7102(-L) (for 1000 l/min)
PFMC7202(-L) (for 2000 l/min)
Analogue Output
Flow Range
IN Side Straight Piping Length and Accuracy (Reference Data)
• The piping on the IN side must have a straight section of piping with a length of 8 cm or more.
If a straight section of piping is not installed, the accuracy can vary by approximately
±
2 % F.S.
∗
“Straight section” means a part of the piping without any bends or rapid changes in the cross
sectional area.
• When the PFMC7501 or 7102 is connected to tubing, use a tube I.D. 9 mm or more just before
the product. The accuracy can vary by approximately
±
2 % F.S. when such tubing is not used.
Model
Flow range
–100 l/min
0 l/min
200 l/min
500 l/min
1000 l/min
2000 l/min
PFMC7501(-L)
PFMC7102(-L)
PFMC7202(-L)
5 l/min
10 l/min
10 l/min
–50 l/min
5 l/min
–25 l/min
500 l/min
525 l/min
525 l/min
1000 l/min
1050 l/min
1050 l/min
20 l/min
20 l/min
–100 l/min
2000 l/min
2100 l/min
2100 l/min
13
PFMC7(-L)
Series