background image

Min. value of the

rated flow range

Voltage output (1 to 5 V)/

Current output (4 to 20 mA)

Max. value of the

rated flow range

A

B

0

Flow

Output

Min. value of the

rated flow range

Voltage output (0 to 10 V)

Max. value of the

rated flow range

D

C

Flow

0

  PFMC7-L only

Output

Pressure loss [kPa]

Flow [l/min]

0

10

20

30

40

50

0

100

200

300

400

500

Supply pressure 
200 kPa

Supply pressure 
400 kPa

Pressure loss [kPa]

Flow [l/min]

0

10

20

30

40

50

0

400

800

1200

1600

2000

Supply pressure 
200 kPa

Supply pressure 
400 kPa

Pressure loss [kPa]

Flow [l/min]

0

10

20

30

40

50

0

200

400

600

800

1000

Supply pressure 
200 kPa

Supply pressure 
400 kPa

OUT

IN

Straight 

piping length

10

9

8

7

6

5

4

3

2

1

0

±

0

±

1

±

2

±

3

±

4

±

5

±

6

Accuracy [% F.S.]

Straight piping length [cm]

Model

Min. value of the rated flow range Max. value of the rated flow range

PFMC7501(-L)

5 l/min

500 l/min

PFMC7102(-L)

10 l/min

1000 l/min

PFMC7202(-L)

20 l/min

2000 l/min

Flow/Analogue Output

1   Analogue output accuracy is within 

±

3 % F.S.

2   A and C will change according to the setting of the zero cut function.

3   The analogue output current from the connected equipment 

should be 2 0 

μ

A or less when selecting 0 to 1 0 V. When more 

than 2 0 

μ

A current fl ows, it is possible that the accuracy is not 

satisfi ed below 0.5 V.

   The minimum value of the rated flow range will change 

according to the setting of the zero cut function.

0 l/min

A

2

B

Voltage output (1 to 5 V)

1

1 V

1.04 V

5 V

Current output

1

4 mA

4.16 mA

20 mA

0 l/min

C

2

D

Voltage output (0 to 10 V)

1, 3

0 V

0.1 V

10 V

Rated fl ow range

Set point range

Display range

Pressure Loss (Reference Data)

PFMC7501(-L) (for 500 l/min)

PFMC7102(-L) (for 1000 l/min)

PFMC7202(-L) (for 2000 l/min)

Analogue Output

Flow Range

IN Side Straight Piping Length and Accuracy (Reference Data)

• The piping on the IN side must have a straight section of piping with a length of 8 cm or more.

If a straight section of piping is not installed, the accuracy can vary by approximately 

±

2 % F.S.

  “Straight section” means a part of the piping without any bends or rapid changes in the cross 

sectional area.

• When the PFMC7501 or 7102 is connected to tubing, use a tube I.D. 9 mm or more just before 

the product. The accuracy can vary by approximately 

±

2 % F.S. when such tubing is not used.

Model

Flow range

 

–100 l/min 

0 l/min 

200 l/min 

500 l/min 

1000 l/min 

2000 l/min

PFMC7501(-L)

PFMC7102(-L)

PFMC7202(-L)

5 l/min

10 l/min
10 l/min

–50 l/min

5 l/min

–25 l/min

500 l/min

525 l/min
525 l/min

1000 l/min

1050 l/min
1050 l/min

20 l/min
20 l/min

–100 l/min

2000 l/min

2100 l/min
2100 l/min

13

PFMC7(-L) 

Series

Summary of Contents for PF2A Series

Page 1: ...product Flow ratio 2 Smallest settable increment 10 1000 1000 L type 5 500 500 L type 5 l min for t PF2A serie l PFG300 Series RoHS min the for the existing es model l Digital Flow Monitor Allows for...

Page 2: ...nding on application The accumulated indication shows the operating flow rate or residual amount of N2 etc in a gas cylinder Flow control of equipment main line and branch line Applications Remote con...

Page 3: ...sub screen is set to mode display ModE LoC is displayed when the data storage lock is enabled Except for when the version does not match or when in SIO mode Display function Displays the output commun...

Page 4: ...Visualization of settings Allows for the monitoring of remote lines Easy screen switching Simple 3 step setting Pressing the and buttons simultaneously for a minimum of 1 second will make the set valu...

Page 5: ...e output free range function Error display function Copy function Selection of power saving mode Functions pp 26 to 28 Output operation Simple setting mode Display colour Delay time setting Digital fi...

Page 6: ...flow type 1 l min PF2M7 L PFG300 PFG300 PF2A PF3A7 H L PFMB PFMC7 L 1 10 1 10 1000 1 20 2000 2 5 500 5 10 1000 1 20 2000 2 5 500 5 2 200 2 1 100 1 0 5 50 5 3 3 2 0 3 0 3 0 1 0 1 0 05 5 0 1 0 0 05 5 5...

Page 7: ...Hysteresis mode Variable Window comparator mode Variable Hysteresis mode Variable Window comparator mode Variable Hysteresis mode Variable Window comparator mode Variable Hysteresis mode Variable Win...

Page 8: ...7...

Page 9: ...L Series How to Order p 11 Specifications p 12 Flow Range p 13 Analogue Output p 13 Pressure Loss p 13 IN Side Straight Piping Length and Accuracy p 13 Internal Circuits and Wiring Examples p 14 Cons...

Page 10: ...equired order with the part numbers listed below Part no Option Note ZS 40 A Lead wire with M8 connector Length 3 m ZS 42 A Bracket Mounting screw for PFMC7501 7102 M3 x 5 2 pcs ZS 42 B Bracket Mounti...

Page 11: ...screen White Main screen 4 digits 7 segments Sub screen 6 digits 11 segments Indicator LED LED ON when switch output is ON OUT1 OUT2 Orange Environmental resistance Enclosure IP65 Withstand voltage 2...

Page 12: ...erseas use only The SI unit type is provided for use in Japan in accordance with the New Measurement Act 7 Fixed units Instantaneous flow l min Accumulated flow L Calibration certificate None A 9 Yes...

Page 13: ...2 The time from when the flow is changed by a step input when the flow rate changes from 0 to the maximum value of the rated flow range instantaneously until the analogue output reaches 90 of the rate...

Page 14: ...A current flows it is possible that the accuracy is not satisfied below 0 5 V The minimum value of the rated flow range will change according to the setting of the zero cut function 0 l min A 2 B Volt...

Page 15: ...Analogue 1 to 5 V output type PFMC7 C NPN 1 output Analogue 4 to 20 mA output type PFMC7 D Max applied voltage 28 V Max load current 80 mA Internal voltage drop 1 V or less C Analogue output 1 to 5 V...

Page 16: ...1 5 V or less L3 Analogue output 1 to 5 V or 0 to 10 V Output impedance 1 k L4 Analogue output 4 to 20 mA Max load impedance 600 Min load impedance 50 Max applied voltage 30 V Max load current 80 mA I...

Page 17: ...3 Flow rectifier Stainless steel 304 4 Sensor chip Silicon 5 Printed circuit board GE4F 6 Gasket HNBR 7 Body Aluminum alloy Anodized 8 Mesh Stainless steel 304 9 Spacer PPS 10 O ring HNBR 11 Holder St...

Page 18: ...Material Heat and oil resistant PVC Finished outside diameter 4 Symbol Model Port size A B D E F H K L N PFMC7501 7102 L Rc1 2 NPT1 2 70 30 60 6 41 2 15 14 26 18 13 6 PFMC7202 L Rc3 4 NPT3 4 G3 4 90 3...

Page 19: ...outputs NPN PNP switching type Analogue voltage output 1 2 SV 2 outputs NPN PNP switching type Analogue current output 2 XY 2 outputs NPN PNP switching type Copy function 1 Can switch between 1 to 5 V...

Page 20: ...w Unit 7 Instantaneous flow l min cfm ft3 min Accumulated flow L ft3 L x 106 ft3 x 106 Display range Instantaneous flow 25 to 525 l min 50 to 1050 l min 100 to 2100 l min Accumulated flow 9 0 to 999 9...

Page 21: ...Sensor Main circuit Main circuit Main circuit Load Load Load Load Load Load Load Load Load Load Load Load Load Load Max 28 V 80 mA Black OUT1 White OUT2 Blue DC Load Load Max 80 mA Brown DC Black OUT...

Page 22: ...llows for mounting in four orientations Bracket configuration allows for mounting in four orientations 1 6 7 2 7 2 5 2 5 2 5 2 30 30 25 1 5 2 7 7 7 20 20 Sensor connector 4 x 2 6 Depth 7 or less Power...

Page 23: ...Panel mount adapter Front protection cover Part no ZS 46 D Power supply output connection lead wire Part no ZS 46 5L Sensor connector Part no ZS 28 CA 4 1 1 to 5 V or 4 to 20 mA Pin no Terminal 1 DC...

Page 24: ...s 24 or more 31 0 0 4 24 or more 31 x n pcs 3 5 x n pcs 1 4 x R 2 o r m o r e 31 0 0 4 Dimensions Multiple 2 pcs or more secure mounting Horizontal Panel mount example Horizontal Panel mount example...

Page 25: ...external inputs and the accumulated value memorizing time interval should not exceed 1 million times Peak Bottom value reset Peak and bottom value are reset Forced output function The output is turned...

Page 26: ...ing it on again OUT2 over current error A load current of 80 mA or more is applied to the switch output OUT2 Instantaneous flow error The flow has exceeded the upper limit of the flow display range De...

Page 27: ...when OFF 1 V or 0 V when 0 to 10 V is selected or 4 mA Also an increase or decrease of the flow will not change the on off status of the output while the forced output function is activated Accumulat...

Page 28: ...pply and then turning it on again Instantaneous flow error The flow rate exceeds the maximum value of the display range Decrease the flow rate Reverse flow error There is a reverse flow equivalent to...

Page 29: ...o the slave monitors reducing setting labor and minimizing the risk of setting mistakes The set value can be copied to up to 10 flow monitors simultaneously Maximum transmission distance 4 m Selection...

Page 30: ...of SMC products with production equipment for the manufacture of weapons of mass destruction WMD or any other weapon is strictly prohibited 2 The exports of SMC products or technology from one countr...

Page 31: ...alia it Latvia 371 67817700 www smc lv info smc lv Lithuania 370 5 2308118 www smclt lt info smclt lt Netherlands 31 0 205318888 www smc nl info smc nl Norway 47 67129020 www smc norge no post smc nor...