<Starting and Stopping> Refer to circuit example (1)
1. Connect air piping to the air supply port <AIR SUR> and connect piping for the fluid to be transferred to the suction port <FLUID IN>
and the discharge port <FLUID OUT>.
2. Using a regulator, set the pilot air pressure within the range of 0.2 to 0.7 MPa. Then, the pump operates when power is applied to the 3
port solenoid valve of the air supply port <AIR SUP>, the sound of exhaust begins from the air exhaust port <AIR EXH> and fluid flows
from the suction port <FLUID IN> to the discharge port <FLUID OUT>.
At this time, the ball valve on the discharge side is in an open state. The pump performs suction with its own power even without
priming. (Dry state suction lifting range: max. 2 m) To restrict exhaust noise, attach a silencer (AN200-02: option) to the air exhaust
port <AIR EXH>.
3. To stop the pump, exhaust the air pressure being supplied to the pump by the 3 port solenoid valve of the air supply port <AIR SUP>.
The pump will also stop if the ball valve on the discharge side is closed.
<Discharge Flow Rate Adjustment>
1. Adjustment of the flow rate from the discharge port <FLUID OUT> is performed with the ball valve connected on the discharge side or
the throttle connected on the air exhaust side. For adjustment from the air side, use of the silencer with throttle ASN2 (port size 1/4)
connected to the air exhaust port <AIR EXH> is effective. Refer to circuit example (1).
2. When operating with a discharge flow rate below the specification range, provide a by-pass circuit from the discharge side to the
suction side to ensure the minimum flow rate inside the process pump. With a discharge flow rate below the minimum flow rate, the
process pump may stop due to unstable operation. Refer to circuit example (2). (Minimum flow rates: PAX1000 0.5
l
/min)
<Reset Button>
1. When the pump stops during operation, press the reset button. This makes it possible to restore operation in case the switching valve
becomes clogged due to foreign matter in the supply air. Maintenance is necessary if the reset button needs to be pressed frequently.
Operation
Piping: Automatically Operated Type, Built-in Pulsation Attenuator
Piping diagram
Pilot air supply port
AIR SUP
Pilot air exhaust port
AIR EXH
Silencer
(Optional)
Reset button
Reset button
Discharge port
FLUID OUT
Suction port
FLUID IN
PROCESS PUMP
Caution
Mounting posture of the pump is set with the bottom surface at the bottom. Air to be supplied to the AIR SUP port should be cleaned and
filtered through AF filter, etc. Air with foreign matter or drainage etc. will have negative effects on the built-in switching valve and will lead
to malfunction. When air needs additional purification, use a filter (Series AF), and a mist separator (Series AM) together.
Maintain the proper tightening torque for fittings and mounting bolts, etc. Looseness can cause problems such as fluid and air leaks,
while over tightening can cause damage to threads and parts, etc.
Air filter
Process pump
PAX1
쏔
12
Strainer
Silencer
Throttle
Transfer fluid
AIR
SUP
AIR
EXH
FLUID
OUT
FLUID
IN
Air supply
Regulator
Ball valve
3 port
solenoid valve
Circuit example (1)