Specifications
0
Option
Automatically operated type
Air operated type
PA3000
JIS Symbol
Symbol
03
Port size
Port size
3/8"
Symbol
Nil
N
F
T
Type
Rc
NPT
G
NPTF
Thread type
Symbol
1
2
Diaphragm material
Diaphragm
material
PTFE
NBR
Automatically
operated
앬
앬
Applicable actuation
Air operated
앬
—
Actuation
Symbol
1
2
Material of body wetted areas
Material of body wetted areas
ADC12 (Aluminum)
SCS14 (Stainless steel)
Model
PA3110
Automatically operated
1 to 20
l
/min
0 to 0.6 MPa
0.2 to 0.7 MPa
Max. 200
l
/min (ANR) or less
80 dB (A) or less
(Option: with silencer, AN200)
1.05 MPa
—
—
Air operated
PTFE
0.1 to 12
l
/min
0 to 0.4 MPa
0.1 to 0.5 MPa
Max. 150
l
/min (ANR) or less
0.75 MPa
50 million times
0.20
Rc, NPT, G, NPTF 3/8" Female thread
Rc, NPT, G, NPTF 1/4" Female thread
PTFE, PFA
1 m (Interior of pump dry)
Up to 6 m (liquid inside pump)
0 to 60
°
C (No freezing)
0 to 60
°
C (No freezing)
Horizontal (with mounting foot at bottom)
General environment
PA3120
PA3210
PA3220
PA3113
Actuation
Port size
Material
Discharge rate
Average discharge pressure
Pilot air pressure
Air consumption
Note 1)
Noise
Withstand pressure
Diaphragm life
Fluid temperature
Ambient temperature
Recommended operating cycle
Pilot air solenoid valve
recommended Cv factor
Mass
Mounting orientation
Packaging
Main fluid suction discharge port
Pilot air supply/exhaust port
Body wetted areas
Diaphragm
Check valve
Dry
Wet
PTFE
ADC12
NBR
NBR
PTFE
SCS14
ADC12
SCS14
1.7 kg
2.2 kg
1.7 kg
2.2 kg
100 million times 50 million times
50 million times
100 million times
PA3213
FLUID OUT
AIR SUP
AIR EXH
FLUID IN
1 1
3
PA
03
FLUID OUT
P1
P2
FLUID IN
Made to order specifications
(For details, refer to pages 724 to 726)
Products complying with ATEX
With air operated reset port
Note)
With operating cycle counting port
Note)
Note) For automatically operated type only.
∗
Each of the values above are for normal temperatures and when the transferred fluid is fresh water.
∗
Refer to page 727 for maintenance parts.
∗
For related products, refer to page 728 and 729.
Note 1) With cycles at 2 Hz or more
Note 2) After initial suction of liquid operating at 1 to 7 Hz, it can be used with operation at lower cycles.
Since a large quantity of liquid will be pumped out, use a suitable throttle in the discharge port if
problems occur.
Note 3) With a low number of operating cycles, even a valve with a small Cv factor can be operated.
Symbol
0
3
Actuation
Automatically operated
Air operated
Process Pump
Automatically Operated Type
(Internal Switching Type)
Air Operated Type
(External Switching Type)
Series
PA3000
Made to
Order
Suction
lifting
range
Symbol
Nil
N
Option
Body only
With silencer
Automatically
operated
앬
앬
Applicable actuation
Air
operated
앬
—
1 to 7 Hz (0.2 to 1 Hz also possible
depending on conditions)
Note 2)
72 dB (A) or less
(excluding the noise from the
quick exhaust and solenoid valve)
Note 3)
How to Order
670
Summary of Contents for PA3000 Series
Page 19: ...688 ...