3-2. Specifications
Specifications
Fluid
Air
Operating method
Double acting
Operating pressure (MPa)
0.2 to 0.6MPa
Proof pressure
0.9MPa
Ambient and operating fluid temperature(
o
C)
-10 to 50
Gripping
Force*
Workpiece
thickness:2mm
160N
Workpiece
thickness:6mm
200N
Residual holding force
0.3 N or less
Lubrication
Non-lube
Weight (g)
590g
Standard for mounting onto the robot
ISO9409-1-50-4-M6
Connector configuration of the accessory
Both side M8 8 pin connector(Socket)
*1 Theoretical holding force (reference value) when a low carbon steel plate is held by entire surface
attraction surface
In the default setting, the auto switch is fixed at the workpiece release position.
* For examples of setting auto switch and setting of mounting position of auto switches, please refer to
the MHM Series catalogue P.12 onwards on our website (www.smcworld.com).
* Auto switches are used for checking the operation of the magnet gripper. They do not guarantee the
actual holding and release of the workpiece. For checking the holding / release of the workpiece, a
proximity sensor should be mounted separately.
Detect the magnet position
For workpiece holding.
Detect the magnet position
for workpiece release.
Detection location at
workpiece is holding position
Detection location at
workpiece release position