3
-
Caution
2) Install an air filter.
Install an air filter close to the upstream side of the valve. A filtration degree of 5mm or less should
be selected.
3) Install an aftercooler, air dryer or drain catch before the filter and take appropriate
measures.
Do not use compressed air containing a lot of condensate, which can cause the operating failure of
the product and other pneumatic equipment. Install an aftercooler, air dryer or drain catch before the
filter and take appropriate measures.
4) Use the product within the specified fluid and ambient temperature range.
When operating at temperatures below 5
o
Operable temperature range is -10 to 60 deg.C (No freezing).
C, water in the circuit may freeze and cause breakage of
seals or malfunction. Corrective measures should be taken to prevent freezing.
Use the product within this range. If the cylinder is used outside of the operable temperature range,
the seal can be worn out due to hardening of the seal and lubrication failure of the grease, causing
air leakage.
For the details of compressed air mentioned above, refer to SMC catalog "Compressed Air
Purification System".
5) Lubrication of non-lubricating cylinder
The product has been lubricated during manufacturing, so it does not require lubrication in service.
For further lubrication, use a lubricant oil equivalent to Polyalphaolefin.
Once lubricant is used in the system, lubrication must be continued because the original lubricant
applied during manufacturing will be washed away.
6) Before piping
Before piping, perform air blow (flushing) or cleaning to remove any cutting chips, cutting oil, dust,
etc. from the piping.
7) Sealant tape
When installing piping or a fitting into a port, prevent cutting chips and sealant material from getting
inside the piping. If a sealant tape is used, leave 1.5 to 2 threads exposed at the end.
!