9
-
3-7-3. Minimum mountable stroke for a cylinder with auto switch(es)
The auto switches applicable to this cylinder may turn on in the entire stroke or two switches may
turn on at the same time if the stroke is 5 or less. Be sure to secure the actual operating distance
4mm or more in order to avoid such errors.
4. Model Selection
4-1. Allowable kinetic energy
Caution
The cylinder will be damaged if kinetic energy exceeds the allowable kinetic energy. Select a cylinder
so that kinetic energy does not exceed the allowable kinetic energy.
Tube I.D. (mm)
6
10
Piston speed (m/s)
0.05 to 0.5
Allowable kinetic energy
(J)
0.012
0.035
Figure 4-1
4-2. Allowable lateral load of the plate
Caution
If this cylinder has an eccentric distance (L) from the plate (the rod end), the load weight (W) should
be not more than the values shown in the graph below. If this cylinder is operated outside of the
limited range, it may reduce the life time or damage the machine.
!
!
2021-06-28 11:26
DC006789