(5) Make sure to wear safety goggles for regular maintenance. 

(6) Please check the following points, and replace the parts as necessary. 

a) Scratches, damage, wear, or corrosion 

b) Air leakage 

c) Squeezing, kinking or twisting of the tubing 

d) Hardening, deterioration or softening of the tubing 

(7) Do not repair or patch the replaced tubing or coupler for reuse. 

(8) Do not disassemble the product, as it may affect the quality of the product.   

                 

 

Handling 

 

    Warning

 

(1) When connecting the plug, hold the plug securely. 

The plug may be disconnected due to the reaction force of the connection. 

(2) To connect the plug, push it firmly into the socket until it clicks into place. 

After connecting the plug, pull it gently to confirm that it will not come out from the socket. If it 

is not connected firmly, the plug can pop out under pressure. Do not touch the sleeve until it is 

confirmed that the plug has been inserted firmly. Otherwise, it may cause malfunction.   

(3) The plug should be upright to the socket when connected.

 

 

Inclined connection can damage the plug and socket, or cause malfunction. 

(4) When disconnecting the plug, hold the plug securely. 

The connected pipings may move due to the reaction force during disconnection or the residual 

pressure on the plug side. 

(5) The sleeve should be upright to the socket when it is moved. 

Rotating in the circumferential direction can cause malfunction. 

(6) Do not push the inside of the socket with a non-compatible plug, or with any type of stick.

 

 

Otherwise, the fluid can jet out and cause danger. Also, the seals can pop out along with the jet 

of fluid, which can break the product. 

(7) If foreign matter adheres to the plug O-ring, wipe it off. 

If the air blow is performed with the air gun air outlet close to the plug O-ring, the Plug O-ring 

may come off. 

(8) If the plug and socket are unable to separate due to a malfunction in the sleeve, do not 

forcefully pull out the plug. View the sleeve from the insertion side of the plug and turn the 

sleeve 3-5 turns clockwise. Then, check that the sleeve works properly. 

If the sleeve still malfunctions, turn the sleeve counterclockwise for 3 to 5 times.   

If the problem is still not solved, loosen the connecting screw for the plug and socket and 

remove the sleeve from the piping. 

 

 

 

2020-11-16 13:19

DP937237

2020-11-17 09:25

DP937237

Summary of Contents for KKA Series

Page 1: ...Doc No KK OMT0085 B PRODUCT NAME S Couplers MODEL Series Product Number KKA Series...

Page 2: ...Contents 1 Safety Instructions 2 11 2 Specifications 12 3 Troubleshooting 12 4 Construction 13 5 Spare Parts 14 1...

Page 3: ...failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The assembl...

Page 4: ...the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded from this...

Page 5: ...ressure can cause disconnection 7 Never pressurize the coupler without check valve in disconnecting condition The connected pipings may break loose causing danger 8 The coupler without check valve lea...

Page 6: ...r or fix the tubing 5 Do not use the product where rotation normally occurs Otherwise the product may be damaged 6 Avoid applications in which vibration or shock is directly applied to the product 7 I...

Page 7: ...C catalog Air Cleaning Systems 3 Use clean air Do not use compressed air that contains chemicals synthetic oils including organic solvents salt or corrosive gases etc as it can cause damage or malfunc...

Page 8: ...patter may cause fire Consult with SMC if using in such an environment 8 Do not use in an environment where water splashes onto the product frequently Rust may be generated easily 9 Do not use the pro...

Page 9: ...an damage the plug and socket or cause malfunction 4 When disconnecting the plug hold the plug securely The connected pipings may move due to the reaction force during disconnection or the residual pr...

Page 10: ...ich is closed while the plug and socket are separated the pipe from the check valve to the closed valve will also be filled with water See the circuit below Once the plug and socket are separated in a...

Page 11: ...KA4 Plug and socket with check valve on both sides KKA4 Plug without check valve Socket with check valve KKA6 Plug withoutcheck valve Socket with check valve KKA6 Plug and socket with check valve on b...

Page 12: ...seep out Remove the excess sealant 4 Insufficient tightening may cause sealing failure or a loose connection 5 Reuse 1 Normally the fittings with sealant can be reused 2 to 3 times 2 Remove loose sea...

Page 13: ...coated Material SUS304 FKM Sealing Male thread with sealant Note 1 The product allows leakage and should not be used for applications such as holding vacuum in a leak tester 3 Troubleshooting In order...

Page 14: ...E 1 Body Stainless steel 304 2 Rear body Stainless steel 304 3 Socket valve Stainless steel 304 4 Collar Stainless steel 304 Fluorine coated 5 Sleeve Stainless steel 304 Plated with Fluorine containin...

Page 15: ...14 5 Spare Parts Description Part No Plug O ring KKA3S P01 KKA4S P01 KKA6S P01 KKA7S P01 KKA8S P01 KKA9S P01...

Page 16: ...anged notation of tightening method Handling Warning No 5 8 9 added 4 14 1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL https www smcworld com Note Specification...

Reviews: