background image

 

 

 

 

Selection 

 

    Warning 

(1) Check the specifications. 

Do not use the product outside of the specified pressure and temperature range, as this may 

cause breakage or operation failure.    (Refer to the specifications.) 

SMC does not guarantee against any damage if the product is used outside of the specification 

range. 

(2) Disassembly and modification prohibited 

Do not disassemble the product or make any modifications, including additional machining. 

This may cause human injury and/or an accident. 

(3) Check if PTFE is compatible with application. 

The sealing agent applied to the threads includes PTFE (polytetrafluoroethylene) powder.   

Check whether or not it could cause issues in your application. 

(4) The product cannot be used as a stop valve to achieve zero leakage. A certain amount of 

leakage is allowed in the product specifications. 

(5) The KKA series cannot be connected to SMC's KK, KKH, KK13 or KK130 series or other 

manufacturer's quick couplers.

 

  This will cause leakage, damage, and disconnection of the 

plug. Check the specifications before use. 

(6) Do not connect or remove the product while it is pressurized or residual pressure remains.   

The pressure can cause disconnection. 

(7) Never pressurize the coupler without check valve in disconnecting condition.

 

The connected 

pipings may break loose, causing danger. 

(8) The coupler without check valve leaks fluid in the piping when it is disconnected. Be careful 

especially when fluid which may cause danger, such as fluid with high temperature and 

pressure, is used. In such cases, we strongly recommend using a product with a stop valve. 

(9) The product will become hot if used with a high temperature fluid.

 If the hot product comes into 

contact with peripheral equipment or parts, it may cause fire. 

  Please attach and detach the plug and socket after keeping the normal temperature. 

 

Caution

 

(1) For a plug and socket connection, select a plug and socket with the same body size. 

If their body sizes are different, they cannot be connected. This will cause leakage, damage, 

and disconnection of the plug. Inserting anything other than the special plug into the socket 

may cause the product failure. 

(2) Do not use in a location where the connecting threads and tubing connection will oscillate or 

rotate. Oscillation or rotation will disconnect the tubing from the thread. 

(3) Do not use the product with flammable, explosive, or toxic substances such as gas, gas fuel, 

and refrigerants. Such substances may permeate from inside to outside of the tubing. 

 

2020-11-16 13:19

DP937237

2020-11-17 09:25

DP937237

Summary of Contents for KKA Series

Page 1: ...Doc No KK OMT0085 B PRODUCT NAME S Couplers MODEL Series Product Number KKA Series...

Page 2: ...Contents 1 Safety Instructions 2 11 2 Specifications 12 3 Troubleshooting 12 4 Construction 13 5 Spare Parts 14 1...

Page 3: ...failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The assembl...

Page 4: ...the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded from this...

Page 5: ...ressure can cause disconnection 7 Never pressurize the coupler without check valve in disconnecting condition The connected pipings may break loose causing danger 8 The coupler without check valve lea...

Page 6: ...r or fix the tubing 5 Do not use the product where rotation normally occurs Otherwise the product may be damaged 6 Avoid applications in which vibration or shock is directly applied to the product 7 I...

Page 7: ...C catalog Air Cleaning Systems 3 Use clean air Do not use compressed air that contains chemicals synthetic oils including organic solvents salt or corrosive gases etc as it can cause damage or malfunc...

Page 8: ...patter may cause fire Consult with SMC if using in such an environment 8 Do not use in an environment where water splashes onto the product frequently Rust may be generated easily 9 Do not use the pro...

Page 9: ...an damage the plug and socket or cause malfunction 4 When disconnecting the plug hold the plug securely The connected pipings may move due to the reaction force during disconnection or the residual pr...

Page 10: ...ich is closed while the plug and socket are separated the pipe from the check valve to the closed valve will also be filled with water See the circuit below Once the plug and socket are separated in a...

Page 11: ...KA4 Plug and socket with check valve on both sides KKA4 Plug without check valve Socket with check valve KKA6 Plug withoutcheck valve Socket with check valve KKA6 Plug and socket with check valve on b...

Page 12: ...seep out Remove the excess sealant 4 Insufficient tightening may cause sealing failure or a loose connection 5 Reuse 1 Normally the fittings with sealant can be reused 2 to 3 times 2 Remove loose sea...

Page 13: ...coated Material SUS304 FKM Sealing Male thread with sealant Note 1 The product allows leakage and should not be used for applications such as holding vacuum in a leak tester 3 Troubleshooting In order...

Page 14: ...E 1 Body Stainless steel 304 2 Rear body Stainless steel 304 3 Socket valve Stainless steel 304 4 Collar Stainless steel 304 Fluorine coated 5 Sleeve Stainless steel 304 Plated with Fluorine containin...

Page 15: ...14 5 Spare Parts Description Part No Plug O ring KKA3S P01 KKA4S P01 KKA6S P01 KKA7S P01 KKA8S P01 KKA9S P01...

Page 16: ...anged notation of tightening method Handling Warning No 5 8 9 added 4 14 1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL https www smcworld com Note Specification...