(4) Surge pressure must be under the maximum operating pressure. 

If the surge pressure exceeds the maximum operating pressure, it will result in damage to 

fittings and tubings. 

(5) Do not use the product with steam. 

The metallic parts may be corroded or the sealant may be deteriorated if the product is used 

with steam for an extended period of time.     

 

Mounting 

 

 

!   

Warning 

(1)  Install  and  operate  the  product  only  after  reading  the  Operation  Manual  carefully  and 

understanding its contents. 

Also, keep the manual where it can be referred to as necessary. 

(2) Maintenance space 

   

  Allow sufficient space for maintenance and inspection. 

(3) Tightening of screws 

   

Refer to “Handling Precautions for screw piping” (page 11). 

(4)  Tubings  can  become  unsecured  and  break  loose  while  the  product  is  in  use,  due  to  the 

deterioration of the tubing or  damage to the fitting. To prevent  the  tubing  from  breaking  loose, 

install a protective cover or fix the tubing. 

(5)  Do  not  use  the  product  where  rotation  normally  occurs.  Otherwise,  the  product  may  be 

damaged. 

(6) Avoid applications in which vibration or shock is directly applied to the product. 

(7) Install a stop valve on the supply pressure side of the socket.

 

Otherwise, it may not be possible 

to perform an emergency shutoff. 

(8) The plug should be upright to the socket when connected. 

   

Inclined connection can damage the plug and socket. 

 

 

Caution 

(1) Preparation before piping 

Before piping is connected, it should be thoroughly flushed with air or washed to remove chips, 

cutting oil and other debris from inside the pipe. 

(2) Wrapping of sealant tape 

   

When screwing piping or fittings into ports, ensure that chips from the pipe threads or sealing 

material do not enter  the piping. Also,  if sealant tape is used,  leave 1 thread ridge exposed  at 

the end of the threads. 

(3) Before mounting, confirm the model, size, etc. 

Also, confirm that there are no scratches, dents or cracks in the product. 

(4)  When  connecting  a  tubing,  consider  factors  such  as  changes  in  the  tubing  length  due  to 

pressure, and allow sufficient leeway. 

 

2020-11-16 13:19

DP937237

2020-11-17 09:25

DP937237

Summary of Contents for KKA Series

Page 1: ...Doc No KK OMT0085 B PRODUCT NAME S Couplers MODEL Series Product Number KKA Series...

Page 2: ...Contents 1 Safety Instructions 2 11 2 Specifications 12 3 Troubleshooting 12 4 Construction 13 5 Spare Parts 14 1...

Page 3: ...failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The assembl...

Page 4: ...the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded from this...

Page 5: ...ressure can cause disconnection 7 Never pressurize the coupler without check valve in disconnecting condition The connected pipings may break loose causing danger 8 The coupler without check valve lea...

Page 6: ...r or fix the tubing 5 Do not use the product where rotation normally occurs Otherwise the product may be damaged 6 Avoid applications in which vibration or shock is directly applied to the product 7 I...

Page 7: ...C catalog Air Cleaning Systems 3 Use clean air Do not use compressed air that contains chemicals synthetic oils including organic solvents salt or corrosive gases etc as it can cause damage or malfunc...

Page 8: ...patter may cause fire Consult with SMC if using in such an environment 8 Do not use in an environment where water splashes onto the product frequently Rust may be generated easily 9 Do not use the pro...

Page 9: ...an damage the plug and socket or cause malfunction 4 When disconnecting the plug hold the plug securely The connected pipings may move due to the reaction force during disconnection or the residual pr...

Page 10: ...ich is closed while the plug and socket are separated the pipe from the check valve to the closed valve will also be filled with water See the circuit below Once the plug and socket are separated in a...

Page 11: ...KA4 Plug and socket with check valve on both sides KKA4 Plug without check valve Socket with check valve KKA6 Plug withoutcheck valve Socket with check valve KKA6 Plug and socket with check valve on b...

Page 12: ...seep out Remove the excess sealant 4 Insufficient tightening may cause sealing failure or a loose connection 5 Reuse 1 Normally the fittings with sealant can be reused 2 to 3 times 2 Remove loose sea...

Page 13: ...coated Material SUS304 FKM Sealing Male thread with sealant Note 1 The product allows leakage and should not be used for applications such as holding vacuum in a leak tester 3 Troubleshooting In order...

Page 14: ...E 1 Body Stainless steel 304 2 Rear body Stainless steel 304 3 Socket valve Stainless steel 304 4 Collar Stainless steel 304 Fluorine coated 5 Sleeve Stainless steel 304 Plated with Fluorine containin...

Page 15: ...14 5 Spare Parts Description Part No Plug O ring KKA3S P01 KKA4S P01 KKA6S P01 KKA7S P01 KKA8S P01 KKA9S P01...

Page 16: ...anged notation of tightening method Handling Warning No 5 8 9 added 4 14 1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL https www smcworld com Note Specification...

Reviews: