![SMC Networks KKA Series Operation Manual Download Page 7](http://html1.mh-extra.com/html/smc-networks/kka-series/kka-series_operation-manual_1299202007.webp)
6
(5) Make sure that no twisting, turning, tensile force or moment load is applied to the S coupler and
pipings.
This may cause damage to the fitting or crushing, bursting or
disconnection of tubing.
(6) Mount so that tubing is not damaged by becoming entangled or
abrasion.
This can cause crushing, bursting or disconnection of tubing, etc.
Air Supply
!
Warning
(1) When there is a large amount of condensate
Compressed air containing a large amount of condensate can cause the malfunction of
pneumatic equipment. An air dryer or water droplet separator should be installed upstream from
the filters.
(2) Drain flushing
If condensate in the drain bowl is not emptied on a regular basis, the bowl will overflow and this
may cause the malfunction of pneumatic equipment.
If the drain bowl is difficult to check and remove, installation of a drain bowl with an auto drain
option is recommended.
For compressed air quality, refer to the SMC catalog "Air Cleaning Systems".
(3) Use clean air.
Do not use compressed air that contains chemicals, synthetic oils including organic solvents,
salt or corrosive gases, etc., as it can cause damage or malfunction of equipment.
!
Caution
(1) Install air filters.
Install an air filter upstream, near the valve. Select an air filter with
a filtration size of 5μm or
smaller.
(2) Take appropriate measures to ensure air quality, such as by providing an aftercooler, air dryer,
or water separator.
Compressed air containing a large amount of condensate can cause the malfunction of
pneumatic equipment. Take measures to ensure air quality, such as by installing an aftercooler,
air dryer, or water separator.
(3) Ensure that the fluid and ambient temperature are within the specified range.
When operating at temperatures below 5
o
C, moisture in the circuit may freeze and cause
breakage of seals or a malfunction. Corrective measures should be taken to prevent freezing.
For detailed information regarding the quality of the compressed air described above, refer to
SMC catalog "Air Cleaning Systems".
Wrap this way.
Leave 1 thread exposed.
Sealant tape
2020-11-16 13:19
DP937237
2020-11-17 09:25
DP937237