40
2) DC mode
·
Positive ions are generated when
"
dp
"
is set for the frequency mode. Negative ions are generated by setting
"
dn
".
·
Refer to 4-4-3. Frequency set mode for further details.
4-3. High voltage power supply module CH number setting
·
When multiple high voltage power supply modules are connected to one controller, the CH number must be
set for each high voltage power supply module to identify the information and set time.
·
The CH number can be assigned from 1 to 4. (Up to 4 modules can be connected). Set the CH number using
the rotary switch on the high voltage power supply module.
·
The CH number set for the high voltage power supply module corresponds with the CH number displayed on
the controller.
·
When multiple high voltage power supply modules are used (max 4 pcs.), the CH number must not be
duplicated. Duplication of the CH number will generate an error (error code:
E7
).
Controller
CH number
High voltage power supply module
CH number set switch
(Fig. shows the setting to 1.)