24
Ⅲ
.Adding a high voltage power supply module
a. High voltage power supply module
to be added should be
·
Connected by D-sub connector at location C.
·
Controller IZTC41 can be connected when IZTP43, IZTP41 and IZTP42 are used together, but IZTP40
cannot be connected.
b. Mounting bracket
·
Mount the brackets to location D.
c. Install the controller and high voltage power supply module
·
Fix the controller and high voltage power supply module at location B using M4 screw.
·
Refer to "6. Dimensions" section for details.
d. High voltage power supply module CH number setting
·
Set the CH number so that it does not duplicate the set number of other channels.
Refer to 4-3. High voltage power supply module CH number setting.
If duplicated, it will be verified as an error.
Refer to "4-5. Alarms" for further details.
2) Installation of DIN rail
·
Use an optional DIN rail mounting bracket.
·
DIN rail mounting brackets are required for mounting the controller and high voltage power supply module.
·
Tighten the fixing brackets that are installed and shipping with specified torque before installation.
Ⅰ
. When the controller and high voltage power supply module are directly connected
a. Removal of the fixing bracket
·
Remove the fixing bracket from the DIN rail mounting bracket at the adjoining faces indicated at
location E.
b. DIN rail mounting bracket
·
Fix the controller and high voltage power supply module to the DIN rail mounting bracket using M4
screws.
Tightening Torque: 1.30 to 1.50 Nm
D : Brackets(accessories)
C : D-sub connector
B: M4 thread
B: M4 thread