3)High voltage cable
Ⅰ
. High voltage cable connection
·
Connect the high voltage cable at the nozzle end to the high voltage power supply module.
·
When connecting and disconnecting the high voltage cable, hold the plugs together with the plug bodies,
and insert or pull out straight. If mounted or removed in an inappropriate direction, the mounting part of
the modular jack may be damaged and cause operation failure.
·
Do not touch part A when handling the
connector. Be careful so that moisture oil or
foreign matter does not adhere to the
connector. Adhesion of moisture, oil or
foreign matter on part A may cause high
voltage electric leakage. If moisture, oil, or
foreign matter adheres to part A, clean it
with ethanol.
·
After connecting the high voltage cable to
the high voltage power supply module, fix
the cable using 2 cross recessed round
head screws (M4x10) included with the
product.
Tightening Torque: 0.49 to 0.53 Nm
Ⅱ
. Wiring high voltage cable
·
When installing the high voltage cable, use the specified high voltage cable holder.
·
Refer to "6. Dimensions" section for details.
a. High voltage cable holder (straight)
·
Use 2 cross recessed round head screws for installing the high voltage cable holder.
(The screws should be prepared by the user. Fixed part thickness 1.6mm, Recommended mounting
screw is cross recessed pan head screw M4x6.)
·
Press the cable positioning it into the holding position and install it.
Tightening torque: 0.19 to 0.21 Nm
Connector
M4 screw
IZTP43
High voltage power supply module
High voltage cable
M4 screw
IZT40-E1
High voltage
cable holder
(straight)
High voltage cable
Holding position
High voltage
connector
(
裏面
)
A
A