-74-
No.PS
※※
-OMV0006-D
●
Product individual parameters (continued)
Index
(dec)
Sub
index
Access
∗
1
Parameter
Data
storage
∗
2
Date
type
∗
3
Initial value
(dec)
Remarks
0x071C
(1820)
0
R/W
Low
er
l
ev
el
s
c
reen
Line name
1st letter
Y
U8
0
Refer to Figure "1st letter (11seg)
of Line name communication data".
0x071D
(1821)
0
R/W
Line name
2nd letter
Y
U8
0
Refer to Figure "2nd to 4th letter
(7seg) of Line name
communication data".
0x071E
(1822)
0
R/W
Line name
3rd letter
Y
U8
0
0x071F
(1823)
0
R/W
Line name
4th letter
Y
U8
0
0x0720
(1824)
0
R/W
Line name
Left side bot
Y
U8
0
0: OFF
(dot OFF)
1: ON
(dot ON)
0x0721
(1825)
0
R/W
Line name
Center bot
Y
U8
0
0x0722
(1826)
0
R/W
Line name
Right side bot
Y
U8
0
0x0456
(1110)
0
R/W
drE
(Selection of
display value
resolution)
Y
U8
0x00
(0)
Setting of display value resolution
0:
Normal resolution
1:
Lower resolution (1/10)
0x0474
(1140)
0
R/W
Cut
(Zero-cut)
Y
U8
0
Display value around 0 is displayed
as 0.
Setting range
0 ~ 10 1.0%
increments
0x0708
(1800)
0
R/W
ECo
(Economy
mode)
Y
U8
0x00
(0)
Setting of power saving mode
0: oFF
1: on
0x0712
(1810)
0
R/W
Pin
(use or unused
of the security
code)
Y
U8
0x00
(0)
Setting of use or unused of the
security code
0:
Unused
1:
Used
0x0713
(1811)
0
R/W
PinCode
(Security code)
Y
U16
0x0000
(0)
Setting of security code
0 ~ 999
0x07D0
(2000)
0
R
M
eas
ur
em
ent
r
el
at
ed
Process data
Conversion
formula
Inclination a
N
F32
Refer to table "Inclination and
intercept to the unit specification".
(Page
0x07D1
(2001)
0
R
Process data
Conversion
formula
Intercept b
N
F32
0x07D2
(2002)
0
R
Peak value
N
U16
0
0x07D3
(2003)
0
R
Bottom value
N
U16
0