[F 1] Setting of OUT1
Page
Item
Explanation
Default setting
Output mode
Either hysteresis mode, window comparator mode, error output or
output off can be selected.
Hysteresis mode
Reversed output
Selects which type of switch output is used, normal or reversed.
Normal output
Pressure setting
Sets the ON and OFF point of the switch output.
ISE20B : 0.500 MPa
ZSE20B : -50.0 kPa
ZSE20BF : 50.0 kPa
Hysteresis
Appropriate setting of the hysteresis will prevent the switch output
from chattering.
ISE20B : 0.050 MPa
ZSE20B : 5.0 kPa
ZSE20BF : 5.0 kPa
Delay time
Delay time of the switch output can be selected.
1.5 ms or less
Display color
Selects the output according to the display color.
OUT1 ON : Green
OUT1 OFF: Red
●
[F 2] Setting of OUT2
Page
Same setting as [F 1] OUT1.
●
Other parameter settings
Item
Page
Default setting
[F 3] Digital filter setting
0.00 s
[F 4] Auto-preset function
Not used
[F 6] Fine adjustment of display value
0%
[F10] Sub display setting
std (Standard)
[F11] Display resolution setting
1000-split
[F14] Zero cut-off setting
0.0
[F80] Power saving mode
OFF
[F81] Security code
OFF
[F90] Setting of all functions
OFF
[F96] Number of pressurizing errors
-
[F98] Output check
N/A (normal output)
[F99] Reset to default settings
OFF