HRX-OM-R039
Chapter 8 Documents
7.4
Stop for a Long Time
HRSE Series
7-6
2.
Remove the tank lid.
3.
Remove the drain plug on the drain port on the piping to discharge the fluid.
An O ring is used for the drain plug. Take care not to damage the O ring.
4.
Confirm that a sufficient amount of the circulating fluid has been
drained from the user’s
machine and piping, and apply air purge from the circulating fluid return port.
5.
After discharging the circulating fluid in the tank, refit the drain plug, clip and close the
tank lid.
6.
Refer to
“7.4-2 Plug to the piping of the product” to mount the plug
(Rc1/2)
to the piping
of the product.
Fig. 7.4-2 Plug to the piping of the product
Circulating fluid
return port (Rc1/2)
Circulating fluid
Outlet (Rc1/2)
Plug
ラグ
Option T
【
For High head pump
】
Circulating fluid
return port (Rc1/2)
Circulating fluid
Outlet (Rc1/2)
Plug
ラグ