background image

No.EX

※※

-OMX1001

 

 

 

 

 

 

 

 

 
 

PRODUCT NAME

 

 

SI unit for EtherNet/IP

TM

 

 

MODEL / Series / Product Number

 

 

EX260-SEN2-X205

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for EX260-SEN2-X205

Page 1: ...No EX OMX1001 PRODUCT NAME SI unit for EtherNet IPTM MODEL Series Product Number EX260 SEN2 X205...

Page 2: ...nd Wiring 11 Installation 11 Wiring 12 LED Indication and Settings 16 Hardware Configuration 19 EDS file and icon 19 Setting using RSLogix5000TM 19 Setting using Network Configurator 24 EtherNet IPTM...

Page 3: ...quipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly Th...

Page 4: ...responsibility a replacement product or necessary parts will be provided This limited warranty applies only to our product independently and not to any other damage incurred due to the failure of the...

Page 5: ...rate in an atmosphere containing flammable or explosive gases Fire or an explosion can result This product is not designed to be explosion proof If using the product in an interlocking circuit Provide...

Page 6: ...it should be used with a UL1310 Class 2 power supply The SI unit is a UL approved product only if they have a mark on the body Use the specified voltage Otherwise failure or malfunction can result Res...

Page 7: ...applied to the product causing damage Take appropriate measures against noise such as using a noise filter when the fieldbus system is incorporated into equipment Otherwise noise can cause malfunctio...

Page 8: ...efer to the PLC manufacturer s manual etc for details of programming and addresses For the PLC protocol and programming refer to the relevant manufacturer s documentation The surface on the product ma...

Page 9: ...8 No EX OMX1001 Model Indication and How to Order EX260 SEN 2 X205 Output specification 2 32 outputs NPN positive common sink Fieldbus EN EtherNet IPTM...

Page 10: ...d operating voltage for SI unit 4 Output connector Output signal interface for valve manifold 5 LED display LED display to indicate the status of the SI unit 1 6 Mounting hole Mounting hole for connec...

Page 11: ...at uses digital communication to exchange signals between field equipment instruments and actuators running on site and a PLC Full duplex Communication system that can send and receive data at the sam...

Page 12: ...L1 120 7 136 7 152 7 168 7 184 7 200 7 216 7 L2 80 96 112 128 144 160 176 L 9 10 11 12 13 14 15 16 L1 232 7 248 7 264 7 280 7 296 7 312 7 328 7 344 7 L2 192 208 224 240 256 272 288 304 mm The above t...

Page 13: ...Data 7 8 BUS IN RJ45 8 pin socket No Designation Description 1 Tx Transmit Data 2 Tx Transmit Data 3 Rx Receive Data 4 5 6 Rx Receive Data 7 8 Connect the BUS IN connector to the upstream device PLC e...

Page 14: ...valve 3 24 V 24 V for solenoid valve 4 SI 0 V for SI unit operation 5 SI 24 V for SI unit operation The power supply connector included as an accessory can be used to supply the power Applicable wire...

Page 15: ...id valve and power supply line for SI unit operation are isolated Be sure to supply power respectively Either single source power or two different power supplies can be used Pay attention not to excee...

Page 16: ...15 No EX OMX1001 Ground terminal Connect the ground terminal to ground Resistance to ground should be 100 ohms or less...

Page 17: ...d Green ON Operating normally Green flashing Either of the following conditions are detected The unit has not been configured correctly The master is idle state Red flashing Recoverable error Red ON U...

Page 18: ...17 No EX OMX1001 Switch setting The switches should only be set with the power supply turned off Open the cover and set the rotary switches and DIP switch with a small flat blade screwdriver...

Page 19: ...s will be maintained 2 DHCP mode IP Address X switch set to 255 The mode to obtain the IP address from the DHCP server The IP address will be lost when the power supply is turned off When receiving th...

Page 20: ...and icon 1 EX260 SEN2 X205 ex260_sen2_x205_24_v zip ex260_sen2_x205_24_v eds ex260 sen2 x205 ico Setting using RSLogix5000TM The method of connecting the SI unit with a Rockwell Automation EtherNet I...

Page 21: ...20 No EX OMX1001 The Select Module Type screen will be displayed Select ETHERNET MODULE Generic Ethernet Module and click on Create...

Page 22: ...2 Comm Format Select the data format of the Connection Parameters 3 IP Address Input the IP Address of the SI unit 4 Assembly Instance Set as follows Input 100 Output 150 Configuration 105 5 Size Set...

Page 23: ...NetWorxTM for EtherNet IPTM Refer to the Manual for RSNetWorxTM for EtherNet IPTM for installation instructions RSNetWorxTM is a trademark of Rockwell Automation When the EDS file is installed the SI...

Page 24: ...23 No EX OMX1001 The Module Properties screen is displayed Perform each setting 1 Name Enter the desired unit name 2 IP Address Enter the IP address that was set for the SI unit 1 2...

Page 25: ...work Configurator for the detailed operation The drawing below shows the OMRONS software Network Configurator It is necessary to install the EDS file for the Network Configurator Refer to the manual f...

Page 26: ...25 No EX OMX1001 Double click on the icon of the master to open the Edit Device Parameter window and move the SI unit from the Unregister Device List to the Register Device List...

Page 27: ...creen For Connection I O Type select Exclusive Owner For the Originator Device select an arbitrary Input Tag Set and Output Tag Set with the same number of bytes as the Output Tag Set and Input Tag Se...

Page 28: ...27 No EX OMX1001 Example Tag Set D00100 2 bytes to the Input and D00150 4 bytes to the Output...

Page 29: ...28 No EX OMX1001 If the allocation has been correctly completed the registered IP address will be displayed with the SI unit icon in the network window...

Page 30: ...switch set to 000 When setting the IP address by remote control first obtain the IP address through the BOOTP DHCP Server then select the Disable DHCP button to hold the IP address 2 Communication set...

Page 31: ...as shown in the figure a If a single solenoid valve is mounted on the standard wiring manifold the output number for the B side valve is skipped Custom wiring for mixed mounting single solenoid valve...

Page 32: ...nd PC Connect SI unit and PC to the same Ethernet network then start the Web browser on the PC The SI unit can be connected to the Web server by inputting SI unit IP address to the Web browser address...

Page 33: ...led Inactive Force output mode disabled 3 Module status SI unit operating condition 16 In 32 Out Device Operational Normal operation 4 Network status Displays the communication status of the SI unit E...

Page 34: ...d entered is successful The mode will be changed to force output mode Initial password is SMCEX260 CAUTION Forced output is valid until selecting Reset or Force output exit Forced output is valid even...

Page 35: ...in red After OUTPUT DATA is edited the output data will be reflected by selecting Execute Reflected OUTPUT DATA is displayed in yellow All output data can be cleared by selecting Reset Forced output m...

Page 36: ...spaces Password change is completed by selecting OK CAUTION Valid character for password is half width alphanumeric and _ and Maximum number of characters for password is 16 Changed password must be...

Page 37: ...36 No EX OMX1001 Properties tab Network information including the SI unit MAC address and communication speed are displayed Performance tab The EtherNet performance of the SI unit is displayed...

Page 38: ...atus of the SI unit is displayed Config tab The EtherNet IPTM QuickConnectTM of the SI unit can be set using the Config tab Similarly it can be set using the QuickConnectTM function of the EtherNet IP...

Page 39: ...FF Refer to fault No 7 SI unit NS LED is red ON SI unit NS LED is red flashing SI unit NS LED is green flashing SI unit MS LED is OFF SI unit MS LED is red ON SI unit MS LED is red flashing Valves do...

Page 40: ...therNet IPTM communication error between the SI unit and the upstream EtherNet IPTM device Check the status of the upstream EtherNet IPTM device Supply power to the upstream EtherNet IPTM device Check...

Page 41: ...action SI unit NS LED is red ON IP address duplication error Check that the IP address is not duplicated Set an IP address that is not duplicated Fault No 9 Fault Probable cause Recommended error hand...

Page 42: ...Mismatch polarity between solenoid valve and SI unit output Check if the solenoid valve common specification matches the output polarity of the SI unit Match polarity between solenoid valve and SI uni...

Page 43: ...htening torque 0 6 Nm Precautions for maintenance 1 Be sure to switch off the power 2 Check there is no foreign matter inside the SI unit 3 Check there is no damage and no foreign matter on the gasket...

Page 44: ...nectors Electrical specifications Item Specifications Current consumption in power supply voltage range Current consumption of controller power supply 21 6 to 26 4 VDC 0 1 A max Solenoid valve power s...

Page 45: ...ation Product type 1Bh Pneumatic Valve Product code F9h Network topology Star Applicable Linear Bus Applicable Ring including DLR Applicable Applicable function QuickConnectTM DLR Device Level Ring IP...

Page 46: ...L L L L Low fixed 0 Input status area Input status area specifications Item Status State SOLV State of power supply for solenoid valve 0 Normal 1 Abnormal 19 V or less Output area mapping Offset Word...

Page 47: ...46 No EX OMX1001 Dimensions...

Page 48: ...3 5207 8249 Fax 81 3 5298 5362 URL https www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manufacturer EtherNet IPTM is a trademark...