background image

Hexagon socket head cap screw 
(M2.5 x 9 L)

Cone points of hexagon 
socket head cap screw 
(M4 x 8 L)

Auto switch mounting bracket 2

Auto switch

Protrusion

Hexagon socket 
head cap screw
(M2.5 x 6 L)

Tie-rod

Auto switch mounting 
bracket 1

BA7T-0

Note)

Hexagon socket head cap screw
(M2.5 x 9 L)

Protrusion

Auto switch mounting bracket

BMB8-0

Note)

Auto switch

Cone points of hexagon 
socket head cap screw
(M4 x 8 L)

Switch mounting rod

Note)  When the auto switch 

mounting bracket is 
ordered by its part 
number, it includes the 
bracket and screws in the 
dashed line. 

Note)  When the auto switch 

mounting bracket is 
ordered by its part 
number, it includes the 
bracket and screws in the 
dashed line. 

Rod Mounting Type 1

Mounting and Moving Method of D-P3DW

  (3)

q

 Insert the protrusion on the bottom of the auto switch into the 

mating part of the mounting bracket and fix the auto switch by 
tightening the hexagon socket head cap screw (M2.5 x 9 L).

w

 Install the mounting bracket on which the auto switch is moun-

ted to the switch mounting rod, and move it to find the detect-
ing position while keeping firm contact between the bottom of 
the auto switch mounting bracket and the cylinder tube.

e

  After checking the detecting position, fix the auto switch 

mounting bracket to the detecting position with the cone points 
of hexagon socket head cap screw (M4 x 8 L).

r

 If the detecting position is changed, go back to step 

w

). 

Note 1) When tightening the cone points of hexagon socket head cap 

screw (M4 x 8 L), keep the tightening torque within 1 to 1.2 N·m. 

Note 2) The torque for tightening the hexagon socket head cap screw 

(M2.5 x 9 L) is 0.2 to 0.3 N·m.  

Note 3)  Tighten the hexagon socket head cap screws evenly.

Applicable cylinder/actuator

Clamp cylinder

Clamp cylinder with lock

Air cylinder

Air cylinder with lock

CKG1

CLK2G

MDB

CDA2

MDNB

CDNA

ø

40 to 

ø

63

ø

40 to 

ø

63

ø

32 to 

ø

63

ø

40, 

ø

50

ø

32 to 

ø

63

ø

40, 

ø

50

Rod Mounting Type 2

Mounting and Moving Method of D-P3DW

  (4)

q

  Install the auto switch mounting bracket 2 to the tie-rod, and 

fix it to the approximate mounting position with the cone points 
of hexagon socket head cap screw (M4 x 8 L) while keeping 
firm contact between the bottom of the auto switch mounting 
bracket 2 and the cylinder tube.

w

 Insert the protrusion on the bottom of the auto switch into the mat-

ing part of the auto switch mounting bracket 1 and fix the auto 
switch and the auto switch mounting bracket 1 temporarily by tight-
ening the hexagon socket head cap screw (M2.5 x 9 L) 1 to 2 turns.

e

 Insert the temporarily tightened mounting bracket 1 to the mat-

ing groove of the mounting bracket 2, and fix the auto switch 
by tightening the hexagon socket head cap screw (M2.5 x 6 L 
and M2.5 x 9 L) after checking the detecting position.

r

 If the detecting position is changed, go back to step 

q

 or 

e

). 

Note 1)  Ensure that the auto switch is covered with the mating groove by a 

minimum of 15 mm to protect the auto switch.

Note 2) When tightening the cone points of hexagon socket head cap 

screw (M4 x 8 L), keep the tightening torque within 1 to 1.2 N·m.

Note 3) The torque for tightening the hexagon socket head cap screw 

(M2.5 x 6 L, M2.5 x 9 L) is 0.2 to 0.3 N·m.  

Note 4)  Tighten the hexagon socket head cap screws evenly.

Applicable cylinder/actuator

Air cylinder

Air cylinder with lock

MDB

CDA2

MDNB

CDNA

ø

80 to 

ø

125

ø

63 to 

ø

100

ø

80 to 

ø

100

ø

63 to 

ø

100

Auto Switch Mounting Bracket Part No. for CK Series
(Including Bracket and Screws)

Series

Bore size (mm)

40

50

63

BMB8-050S

CKG1
CLK2G

  Differences in color and glossiness of the metal surface treatment do 

not affect the performance. Due to the characteristics of the chromate 
treatment (trivalent) applied to the whole body of the auto switch mount-
ing bracket, the color may be slightly different between manufacturing 
lots. However, this will not reduce the corrosion resistance. 

Auto Switch Mounting Bracket Part No. for MB Series
(Including Bracket and Screws)

Series

Bore size (mm)

32

40

50

63

80

100

125

BMB8-032S

BMB8-050S

BA7T-063S

BA7T-080S

MDB
MDNB (32 to 100)

Auto Switch Mounting Bracket Part No. for CA Series
(Including Bracket and Screws)

Series

Bore size (mm)

40

50

63

80

100

BMB8-050S

BA7T-063S

BA7T-080S

CDA2
CDNA

8

Series 

D-P3DW

 

Magnetic Field Resistant

2-Color Display Solid State Auto Switch

D-P3DW-A.qxd  08.9.19 2:36 PM  Page 11

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Summary of Contents for D-P3DW* Series

Page 1: ...in an environment which generates a magnetic field disturbance AC magnetic field If the current of the AC welding machine is 16000 A or lower the switch can be used even if the distance between the welding conductor and the cylinder actuator or auto switch is 0 mm RoHS compliant Existing model D P4DW D P3DW New Volume is reduced by 70 compared to existing switches Magnetic Field Resistant 2 Color ...

Page 2: ...connector M12 Improved maintenance ability As an auto switch mounting bracket is fixed on the cylinder actuator side the position does not need to be readjusted when the auto switch is replaced Welding current ampere Distance between welding gun and auto switch mm 60 50 40 30 20 10 0 10000 20000 30000 Image of welding current and safety zone Danger zone Safety zone Image of danger zone If the curr...

Page 3: ...to Switch Example CKG1A40 100Y P3DWSC S n Nil 2 pcs 1 pc n pcs Number of auto switches Auto switch Nil None For auto switch model refer to How to Order When cylinders actuators are ordered with an auto switch the cylinder actuator auto switch and auto switch mounting bracket including screws are enclosed When the auto switch is ordered on its own the auto switch mounting bracket is not included In...

Page 4: ...h indicator light D P3DWSC D P3DWSE Lead wire Oilproof heavy duty vinyl cable ø4 8 0 5 mm2 2 cores Impact resistance Switch 1000 m s2 Connector 300 m s2 Insulation resistance 50 MΩ or more at 500 VDC Mega between lead wire and case Withstand voltage 1000 VAC for 1 minute between lead wire and case Ambient temperature 10 to 60 C Enclosure IEC60529 standard IP67 Polarity Non polar Magnetic Field Res...

Page 5: ...an be used even if the distance between the welding conductor gun cable and the cylinder actuator or auto switch is 0 mm Please contact SMC when the AC welding current exceeds 16000 A OUT Brown OUT Blue Unit g Mass Auto switch model Lead wire length m 0 5 3 5 20 102 168 D P3DW L Z Dimensions Body Auto switch mounting bracket For round groove mounting BQ3 032S Auto switch mounting bracket For squar...

Page 6: ...100 Hs Auto Switch Proper Mounting Position and Its Mounting Height CKG1 CLK2G MDB MDNB CDA2 CDNA CDQS CDQ2 CDLQ MGP MLGP MGPS CKQG CLKQG 3 Series D P3DW S20 201A D P3DW qxd 10 1 28 10 59 AM Page 4 Courtesy of Steven Engineering Inc 230 Ryan Way South San Francisco CA 94080 6370 Main Office 650 588 9200 Outside Local Area 800 258 9200 www stevenengineering com ...

Page 7: ...12 17 5 32 34 5 38 44 47 5 57 5 67 5 mm MGP MLGP Bore size mm A B Hs 25 32 40 50 63 80 100 1 5 2 5 6 5 4 5 7 10 14 5 5 4 6 5 8 5 11 15 5 20 5 30 33 37 42 5 49 5 48 58 Ht 78 5 90 mm MGPS Bore size mm A B Hs 50 80 4 9 5 8 13 5 42 5 48 Ht 78 5 mm CKQG Bore size mm A B Hs 50 5 18 44 mm CLKQG Bore size mm A B Hs 50 40 50 44 mm CDQS Bore size mm A B Hs 25 1 5 0 0 32 mm Note The mounting position should ...

Page 8: ... ø25 to ø100 MGPS ø50 ø80 MLGP ø25 to ø100 1 pc 2 pcs 15 15 mm n pcs CDA2 Number of auto switches ø40 to ø100 ø40 to ø100 2 pcs Different sides Same side 1 pc 15 85 Support brackets other than center trunnion Center trunnion mm 15 50 n 2 4 6 8 n 2 2 85 50 n 4 8 12 16 n 4 2 n pcs MDNB Number of auto switches ø32 to ø100 2 pcs Different sides Same side 1 pc 15 Support brackets No center trunnion mm ...

Page 9: ... size mm mm Note Since this is a guideline including hysteresis not meant to be guaranteed Assuming approximately 30 dispersion Value may greatly change depending on the surrounding environment 6 Series D P3DW Magnetic Field Resistant 2 Color Display Solid State Auto Switch D P3DW A qxd 08 9 19 2 36 PM Page 9 Courtesy of Steven Engineering Inc 230 Ryan Way South San Francisco CA 94080 6370 Main Of...

Page 10: ...ch mounting bracket temporarily by tightening the hexagon socket head cap screw M2 5 x 9 L 1 to 2 turns w Insert the temporarily tightened mounting bracket into the mat ing groove of the cylinder actuator and slide the auto switch onto the cyinder actuator through the groove e Check the detecting position of the auto switch and fix the auto switch firmly with the hexagon socket head cap screw M2 5...

Page 11: ...e keeping firm contact between the bottom of the auto switch mounting bracket 2 and the cylinder tube w Insert the protrusion on the bottom of the auto switch into the mat ing part of the auto switch mounting bracket 1 and fix the auto switch and the auto switch mounting bracket 1 temporarily by tight ening the hexagon socket head cap screw M2 5 x 9 L 1 to 2 turns e Insert the temporarily tightene...

Page 12: ...ipment including our products must be performed by an operator who is appropriately trained and experienced 3 Do not service or attempt to remove product and machinery equipment until safety is confirmed 1 The inspection and maintenance of machinery equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed 2 When the product is to be ...

Page 13: ...iod which is clearly our responsibility a replacement product or necessary parts will be provided This limited warranty applies only to our product independently and not to any other damage incurred due to the failure of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 3 Vacuum pads ar...

Page 14: ...el 5 Ensure sufficient clearance for maintenance activities When designing an application be certain to allow sufficient clearance for maintenance Caution 1 Confirm proper insulation of wiring Be certain that there is no faulty wiring insulation contact with other circuits ground fault improper insulation between termi nals etc Damage may occur due to excess current flow into a switch 2 Do not wir...

Page 15: ...o switch s inter nal circuit elements Avoid sources of surge generation and disorganized lines 6 Avoid accumulation of iron waste or close contact with magnetic substances When a large amount of iron waste such as machining chips or spatter is accumulated or a magnetic substance some thing attracted by a magnet is brought into close proximity with a cylinder actuator with auto switches it may caus...

Page 16: ...SOUTH KOREA SMC Pneumatics Korea Co Ltd TAIWAN SMC Pneumatics Taiwan Co Ltd THAILAND SMC Thailand Ltd NORTH AMERICA CANADA SMC Pneumatics Canada Ltd MEXICO SMC Corporation Mexico S A de C V U S A SMC Corporation of America SOUTH AMERICA ARGENTINA SMC Argentina S A BOLIVIA SMC Pneumatics Bolivia S r l BRAZIL SMC Pneumáticos do Brasil Ltda CHILE SMC Pneumatics Chile S A VENEZUELA SMC Neumatica Venez...

Reviews: