-21-
No.D-
※
S-OMU0002-A
•Product individual parameters 2
Index
(decimal
number)
Subindex
Access
1
Parameter name
Format
Length
Initial
value
DS
Selection range
Value/Range
0x3A
(58)
0
R/W
Teach-in channel
Int
8 bit
0
Y
0: default BDC
= BDC1
1: BDC1
2: BDC2
3: BDC3
4: BDC4
5: Measuring
range
0x3B
(59)
0
R
Teach-in status
Record
1
Byte
N
0x0040
(64)
0
R/W
Device/function
name
String
16
Byte
***
N
0x0079
(121)
0
R/W
Pin 2 configuration
Unit
8 bit
37
Y
0: Deactivated
37: QA-I
(Analogue
current)
38: QA-U
(Analogue
voltage)
0x00CC
(204)
0
R/W
Find Me
Unit
8 bit
0
N
0: Deactivated
1: LEDs blinking
with 1 Hz
0x00E3
(227)
0
R/W
Notification Enable
Unit
8 bit
0
Y
0: All enabled
1: All disabled
0x00E5
(229)
1
R
Position
of magnet
Position
bit(8)
16 bit
N
Travel distance
[mm]
30000:
out of
measuring
range
2
Position
qualifier
bit(0)
8 bit
N
1
0x3000
(12288)
1
R/W
Measuring
range
Measuring
range
start
bit(16)
16 bit
Refer
to P.
Y
0 to 4000
Range start -
end
≧
20
2
Measuring
range end
bit(0)
16 bit
Refer
to P.
Y
1: 0: Magnet within measuring range (Within measuring range)
1: Magnet out of measuring range but within working range (at the front)
2: Magnet out of measuring range but within working range (at the cable outlet)
3: Magnet is out of working range (Out of measuring range)