-15-
No.D-
※
S-OMU0002-A
○Switch output mode
●
There are 4 modes for switch output. Follow the conditions below.
•SP1 + Hysteresis < Measuring range
•SP2 + Hysteresis < Measuring range
•SP1
-
Hysteresis >0
•SP2
-
Hysteresis > 0
(1) Single switch point mode
Normal output
Reversed output
(2) Auto switch mode
Normal output
Reversed output
<Additional condition>
SP1 + 1.5 mm + 1.5
hysteresis < Operation range
SP1 - 1.5 mm - 1.
hysteresis >
0
ON range is approx. 3 mm. (The projections are not included in the dimension.)
(3) Window mode
Normal output
Reversed output
<Additional condition>
Hysteresis <
SP1 - SP2
(4) 2 point mode
(can be sent only in IO-Link mode)
Normal output
Reversed output
<Additional condition>
Can be used without IO-Link connection.
○Hysteresis
Default value for each mode is 0.5 mm. This can be changed between 0.05 and 20 mm by using IO-Link.