1.
Outline
This operation manual explains
“rack and pinion type compact rotary actuator”.
hen using the product, load (moment of inertia), rotation time and other factors have to be considered.
So, confirm the specification of the product prior to use.
1-1 Specifications
-17-
Table1
Specification-1
Size
10
15
20
30
40
Operating fluid
Air
(
Non-lube
)
Max. operating pressure
0.7 MPa
1.0 MPa
Min. operating pressure
0.15 MPa
0.1 MPa
Ambient temp. and operating
fluid temp.
0
~
60
℃(
No freeze
)
Cushion
Rubber cushion
No. Air cushion
Angle adjustment
±5°
Rotation angle
80°
~
100°
、
170°
~
190°
、
350°
~
370°
Port size
M5×0.8
Rc 1/8
,
G 1/8
,
NPT 1/8
,
NPTF 1/8
Supporting style
Basic type
Output(N
・
m)
0.3
0.75
1.8
3.1
5.3
Table 2
Specification-2
Size
Allowable kinetic energy
Safe adjustment range of
rotating time
Allowable kinetic energy
(
mJ
)
Cushion
angle
No
air
cushion
Rubber
cushion
Air
cushion
Rotation time
(s/90
゚
)
10
-
0.25
-
-
0.2
~
0.7
15
-
0.39
-
-
0.2
~
0.7
20
25
-
120
40°
0.2
~1
30
48
-
250
40°
0.2
~1
40
81
-
400
40°
0.2
~1
Allowable kinetic energy of cushion type is the max. adsorbing energy when the cushion
needle adjustment is optimum. Operation with the speed lower than adjustment range lead
to cause stick clip or termination of operation.
Table 3
Specification-3
Size
Weight
(
g
)
Internal capacity
(
cm
3
)
90
゜
180
゜
360°
90
゜
180
゜
360°
10
120
150
200
1.2
2.2
4.3
15
220
270
380
2.9
5.5
10.7
20
600
700
1000
7.1
13.5
26.3
30
900
1100
1510
12.1
22.9
44.7
40
1400
1600
2280
20.5
39
76
2020-10-13 10:36
DI987004