![SMC Networks AXTS040 2 X2 Series Operation Manual Download Page 11](http://html1.mh-extra.com/html/smc-networks/axts040-2-x2-series/axts040-2-x2-series_operation-manual_1299308011.webp)
-11 -
7.
Mounting
Before connecting the valve, flush the piping of the upstream (supply pressure port side) and
downstream (control equipment port side) to eliminate particles in the piping and foreign matter
and scales generated during piping.
8.
Environment
Please contact SMC if the product is used where corrosive gas, chemicals and their solutions,
water vapor, or seawater droplets exist, or temperature exceeds 50
o
C, or vibration occurs.
9.
Lubricant oil
The product has been lubricated for life by the manufacturer, and does not require lubrication in
service.
10.
Air Source
①
Install an air filter of 5μm to the upstream of the solenoid valve (air source side). Install the
filter as close to the valve as possible. Air resistance is large and the flow decreases when
the filter element is clogged. Clean the filter element.
②
Carbon powder and oil depleting materials generated from the air supply (mainly from the
compressor) can cause an increase in friction on the spool causing it to stick. This may
result in the valve falling to operate. If the supply pressure is pressurized for a long time with
low quality air, then carbon powder or oil depleting materials contained in the compressed air
might accumulate in the space between the spool and sleeve, which may cause the spool to
stick. In this situation, the type of the compressor lubricating oil should be replaced with a
good quality compressor lubrication oil that generates less oxidants. It is possible to prevent
fine foreign matter from entering the valve by mounting a mist separator with high filtration
accuracy (AM series) after a normal filter (AF series). If the product is used for extended
period of time where a large amount of oil depleting materials exist, the cartridge element
will be clogged and pressure drop becomes large. When the differential pressure reaches
0.1MPa or more, or the product is used more than a year, replace the cartridge element.
Replace the element at least within 3 years of use.
③
If the product is used with the filter case fully accumulated with drain, it may enter into the
downstream, causing operation failure of the valve. Discharge drain regularly. Cycle time
for drain discharge is different depending on the weather and air consumption. The piping
should be slightly sloped so that generated drain is pooled in one place with the drain cock
for discharge to the outside. The slope for the piping should be 1:100.
Refer to "SMC Air Preparation System" for further details on air source. For details of filter,
mist separator and regulator, refer to the operation manual for each parts.
AF series for the filter, AM series for the mist separator, and AR series for the regulator.